Optical and mechanical clot detection methodologies: A comparison study for routine coagulation testing
dc.contributor.author | Tekkesin, Nilgün | |
dc.contributor.author | Kılınç, Cumhur | |
dc.date.accessioned | 2024-02-29T12:57:16Z | |
dc.date.available | 2024-02-29T12:57:16Z | |
dc.date.issued | 2012 | en_US |
dc.department | Dicle Üniversitesi, Tıp Fakültesi, Temel Tıp Bilimleri Bölümü, Tıbbi Biyokimya Ana Bilim Dalı | en_US |
dc.description.abstract | Background: Automated coagulation analyzers are preferred to meet increasing coagulation test volume. Two distinct technological families exist based on optical and mechanical clot detection methodologies. Which one is superior to the other is still a conflict and needs new studies. Methods: We have compared prothrombin and activated partial thromboplastin results obtained with mechanical method with those obtained by photo-optical method used routinely in our specialized laboratory. Results: The instrumental results showed good precision ranging between 0.7% and 1.8% coefficient of variation. Statistical analysis demonstrated an excellent correlation between the photo-optical and mechanical analyzers for PT (R2 0.97), and aPTT (R2 0.85). Conclusion: Correlation between the two clot-detection systems was maintained even when measuring turbid samples (R2 ≥ 0.97 for two tests). | en_US |
dc.identifier.citation | Tekkesin, N. ve Kılınç, C. (2012). Optical and mechanical clot detection methodologies: A comparison study for routine coagulation testing. Journal of Clinical Laboratory Analysis, 26(3), 125-129. | en_US |
dc.identifier.doi | 10.1002/jcla.21497 | |
dc.identifier.endpage | 129 | en_US |
dc.identifier.issn | 1098-2825 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.pmid | 22628225 | |
dc.identifier.scopus | 2-s2.0-84861465539 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 125 | en_US |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/epdf/10.1002/jcla.21497 | |
dc.identifier.uri | https://hdl.handle.net/11468/13444 | |
dc.identifier.volume | 26 | en_US |
dc.identifier.wos | WOS:000304397200001 | |
dc.identifier.wosquality | Q3 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Kılınç, Cumhur | |
dc.language.iso | en | en_US |
dc.relation.ispartof | Journal of Clinical Laboratory Analysis | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Blood coagulation | en_US |
dc.subject | Clot detection | en_US |
dc.subject | Factors | en_US |
dc.subject | Mechanical detection | en_US |
dc.subject | Optical detection | en_US |
dc.subject | Partial thromboplastin time | en_US |
dc.subject | Prothrombin time | en_US |
dc.title | Optical and mechanical clot detection methodologies: A comparison study for routine coagulation testing | en_US |
dc.title | Optical and mechanical clot detection methodologies: A comparison study for routine coagulation testing | |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Optical and Mechanical Clot Detection Methodologies.pdf
- Boyut:
- 463.18 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası
Lisans paketi
1 - 1 / 1
[ X ]
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: