Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population
dc.authorid | 0000-0003-2471-1942 | en_US |
dc.authorid | 0000-0002-2456-7381 | en_US |
dc.contributor.author | Çelebi, Adalet | |
dc.contributor.author | Gülsün, Belgin | |
dc.date.accessioned | 2024-01-29T10:37:28Z | |
dc.date.available | 2024-01-29T10:37:28Z | |
dc.date.issued | 2023 | en_US |
dc.department | Dicle Üniversitesi, Diş Hekimliği Fakültesi, Ağız-Diş-Çene Hastalıkları ve Cerrahisi Bölümü | en_US |
dc.description.abstract | It was aimed to evaluate the frequency of accessory mental foramen (AMF) and accessory infraorbital foramen (AIOF) and analyse the correlation between these two foramina using cone-beam computed tomography (CBCT). The retrospective study reviewed the CBCT images of 1020 patients. The rates of AMF and AIOF were evaluated according to sex and age distributions. Correlations between the localizations of AMF and AIOF in the right and left jaws and the correlations between the occurrences of these foramina were evaluated. In the CBCT images of the 1020 patients, AMFs were detected in 48 patients, among which 14 were in the right half jaw, and 34 were in the left half jaw. AIOFs were detected in 143 patients, among which 65 were in the right half jaw, and 78 were in the left half jaw. Recognising and detecting AMF and AIOF with CBCT is important in terms of preventing complications that may occur in surgical procedures. | en_US |
dc.identifier.citation | Çelebi, A. ve Gülsün, B. (2023). Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population. Australian Endodontic Journal, 49(1), 13-19. | en_US |
dc.identifier.doi | 10.1111/aej.12693 | |
dc.identifier.endpage | 19 | en_US |
dc.identifier.issn | 1329-1947 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.pmid | 36177731 | |
dc.identifier.scopus | 2-s2.0-85138903389 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 13 | en_US |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/epdf/10.1111/aej.12693 | |
dc.identifier.uri | https://hdl.handle.net/11468/13294 | |
dc.identifier.volume | 49 | en_US |
dc.identifier.wos | WOS:000861701300001 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Gülsün, Belgin | |
dc.language.iso | en | en_US |
dc.publisher | John Wiley and Sons Inc | en_US |
dc.relation.ispartof | Australian Endodontic Journal | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Accessory infraorbital foramen | en_US |
dc.subject | Accessory mental foramen | en_US |
dc.subject | Cone-beam computed tomography (CBCT) | en_US |
dc.title | Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population | en_US |
dc.title | Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population | |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- Evaluation of accessory mental foramen and accessory infraorbital foramen with cone-beam computed tomography in Turkish population.pdf
- Boyut:
- 958.93 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası
Lisans paketi
1 - 1 / 1
[ X ]
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: