Cardiac device-related infective endocarditis; analysis of 15 cases
dc.contributor.author | Elbey, Mehmet Ali | |
dc.contributor.author | Eren, Nihan Kahya | |
dc.contributor.author | Kalkan, Mehmet Emin | |
dc.contributor.author | Demirtas, Sinan | |
dc.contributor.author | Kahraman, Fatih | |
dc.contributor.author | Sayin, Rasit | |
dc.contributor.author | Oylumlu, Mustafa | |
dc.date.accessioned | 2024-04-24T17:27:48Z | |
dc.date.available | 2024-04-24T17:27:48Z | |
dc.date.issued | 2013 | |
dc.department | Dicle Üniversitesi | en_US |
dc.description.abstract | Objectives: We aimed to investigate the demographic and clinical characteristics, echocardiographic and microbiologic features, and outcomes of patients with permanent pacemaker (PM), and implantable cardioverter-defibrillator (ICD) - related endocarditis in this study. Study design: The study population consisted of 15 patients with permanent PM and ICD-related endocarditis. Data on patients'demographic characteristics, medications used, clinical, and microbiological data, echocardiographic findings, types, and outcomes of surgical treatments were recorded. Results: The mean age of the patients was 57+/-16. Seven patients (47%) were female. Of the 15 patients with permanent PM and ICD-related endocarditis, 5 died during in-hospital follow-up (33%). In four patients (27%) pulmonary embolism developed. Culture-negative endocarditis was detected in 5 cases (33%). Staphylococci were the most common causative organisms in 60% of the patients. Three (20%). patients underwent surgical treatment Conclusion: Cardiac device-related endocarditis remains a rare complication of intracardiac device implantation still with higher mortality rates. | en_US |
dc.identifier.doi | 10.5543/tkda.2013.32708 | |
dc.identifier.endpage | + | en_US |
dc.identifier.issn | 1016-5169 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 23666300 | |
dc.identifier.scopus | 2-s2.0-84876712240 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 131 | en_US |
dc.identifier.uri | https://doi.org/10.5543/tkda.2013.32708 | |
dc.identifier.uri | https://hdl.handle.net/11468/20202 | |
dc.identifier.volume | 41 | en_US |
dc.identifier.wos | WOS:000421883000006 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | en_US |
dc.publisher | Turkish Soc Cardiology | en_US |
dc.relation.ispartof | Turk Kardiyoloji Dernegi Arsivi-Archives of The Turkish Society of Cardiology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Defibrillators | en_US |
dc.subject | Implantable/Adverse Effects | en_US |
dc.subject | Endocarditis/Diagnosis/Prevention & Control /Therapy | en_US |
dc.subject | Pacemaker | en_US |
dc.subject | Artificial | en_US |
dc.subject | Cardiology | en_US |
dc.title | Cardiac device-related infective endocarditis; analysis of 15 cases | en_US |
dc.title | Cardiac device-related infective endocarditis; analysis of 15 cases | |
dc.type | Article | en_US |