A New and Practical Aspartate Aminotransferase Test in Vaginal Washing Fluid for the Detection of Preterm Premature Rupture of Membranes
[ X ]
Tarih
2008
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Karger
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Objectives: To determine whether measurement of aspartate aminotransferase (Ast) and alanine aminotransferase (Alt) levels in vaginal fluid is useful for the diagnosis of preterm premature rupture of membranes (PPROM). Study Design: The PPROM group and normal pregnancy group consisted of 36 and 48 pregnant patients between 26 and 36 weeks' gestation, respectively. Vaginal fluid Ast and Alt levels were measured in both groups. Results: Vaginal fluid Alt level was not statistically significant in the PPROM group as compared with the control group (p = 0.064). Vaginal Ast level was statistically significant in the PPROM (14.4 +/- 17.46 U/l) group as compared with the control group (3.08 +/- 7.8 U/l; p = 0.001). The optimal cutoff value of 3 IU/l for Ast gave a sensitivity level of 91% at a specificity of 83%, with positive and negative predictive values of 80 and 93%, respectively. Conclusion: Ast measurement from vaginal washing fluid appears to be a useful marker for the detection of PPROM. Copyright (C) 2008 S. Karger AG, Basel
Açıklama
Anahtar Kelimeler
Preterm Premature Rupture Of Membranes, Aspartate Aminotransferase, Alanine Aminotransferase
Kaynak
Fetal Diagnosis and Therapy
WoS Q Değeri
Q4
Scopus Q Değeri
Q1
Cilt
24
Sayı
4