Combined use of retraction and torque arch with mini-screws: A cephalometric study

dc.authorid0000-0003-0728-6833en_US
dc.authorid0000-0002-5044-457Xen_US
dc.authorid0000-0002-3876-5346en_US
dc.contributor.authorAmasyalı, Mihri
dc.contributor.authorSabuncuoğlu, Fidan Alakuş
dc.contributor.authorKaraçay, Şeniz
dc.contributor.authorDoğru, Mehmet
dc.contributor.authorAltuğ, Handan
dc.date.accessioned2024-01-09T06:37:22Z
dc.date.available2024-01-09T06:37:22Z
dc.date.issued2018en_US
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Ortodonti Bölümüen_US
dc.description.abstractObjective: Our objective was to investigate and quantify the treatment of micro-implant-aided retraction and torque (R&T) arch on dentofacial structures. Methods: Twelve patients (mean age 21.2 years) who required orthodontic camouflage treatment were included in the study. Following the canine distalization, mini-screws were placed between maxillary first molars and second premolars, and R&T arch was applied for the retraction of incisors. The vertical retraction arms of the arch were adjusted between the apex of the lateral incisor and the alveolar bone so that the retraction force passed through the center of resistance of four incisors and forced the incisors to bodily retraction. Closed coil-springs applying 150 gr of force were used to retract the incisors. The retraction period lasted for 217±34 days. Results: SNA and NV-A decreased (p<0.05), indicating alveolar bone remodeling around Point A. The reduction in the SNA caused a statistically significant decrease in the ANB (p<0.01). SN/1, NA/1, NA-1, and overjet decreased significantly (p<0.01), depending on the retrusion of the incisors. The distances from the apex and incisal point of the central incisor to the SV reference plane also decreased significantly (p[removed]0.05). Conclusion: A combined use of R&T arch with mini-screws is an effective method to retract the incisors without anchorage loss. The type of movement is nearly parallel.en_US
dc.identifier.citationAmasyalı, M., Sabuncuoğlu, F. A., Karaçay, Ş., Doğru, M. ve Altuğ, H. (2018). Combined use of retraction and torque arch with mini-screws: A cephalometric study. Turkish Journal of Orthodontics, 31(1), 1-6.en_US
dc.identifier.doi10.5152/TurkJOrthod.2018.17031
dc.identifier.endpage6en_US
dc.identifier.issn2528-9659
dc.identifier.issue1en_US
dc.identifier.pmid30112506
dc.identifier.scopus2-s2.0-85062727158
dc.identifier.scopusqualityQ2
dc.identifier.startpage1en_US
dc.identifier.trdizinid311052
dc.identifier.urihttps://cms.galenos.com.tr/Uploads/Article_53468/Turk%20J%20Orthod-31-1-En.pdf
dc.identifier.urihttps://hdl.handle.net/11468/13158
dc.identifier.volume31en_US
dc.identifier.wosWOS:000436159100001
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorDoğru, Mehmet
dc.language.isoenen_US
dc.publisherAves Yayıncılıken_US
dc.relation.ispartofTurkish Journal of Orthodontics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectArchen_US
dc.subjectMini screwen_US
dc.subjectRetraction and torqueen_US
dc.titleCombined use of retraction and torque arch with mini-screws: A cephalometric studyen_US
dc.titleCombined use of retraction and torque arch with mini-screws: A cephalometric study
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Combined use of retraction and torque arch with mini-screws.pdf
Boyut:
567.63 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: