The use of Bacillus subtilis immobilized on Amberlite XAD-4 as a new biosorbent in trace metal determination

dc.contributor.authorDogru, Mehmet
dc.contributor.authorGul-Guven, Reyhan
dc.contributor.authorErdogan, Sait
dc.date.accessioned2024-04-24T16:15:06Z
dc.date.available2024-04-24T16:15:06Z
dc.date.issued2007
dc.departmentDicle Üniversitesien_US
dc.description.abstractThe present work proposes the use of Bacillus subtilis immobilized on Amberlite XAD-4 as new biosorbent in trace metal determination. The procedure is based on the biosorption of Cu and Cd ions on a column of Amberlite XAD-4 resin loaded with dried, dead bacterial components prior to their determination by flame AAS. Various parameters such as pH, amount of adsorbent, eluent type and volume, flow rate of solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH values of quantitative sorption for Cu and Cd were found to be 7.0 and 7.5, respectively. These metal ions can be desorbed with 1 M HCl (recovery, 96-100%). The,sorption capacity of the resin was 0.0297 and 0.035 mmol g(-1) for Cu(2+) and Cd(2+), respectively. The tolerance limit of some electrolytes were also studied. This procedure was applied to Cu(2+) and Cd(2+) determination in aqueous solutions, including river and well water systems. In order to evaluate the accuracy of the proposed procedure, the certified reference materials, NRCC-SLRS-4 Riverine water and LGC7162 Strawberry leaves were analyzed. (C) 2007 Elsevier B.V. All rights reserved.en_US
dc.identifier.doi10.1016/j.jhazmat.2007.03.066
dc.identifier.endpage173en_US
dc.identifier.issn0304-3894
dc.identifier.issue1en_US
dc.identifier.pmid17467896
dc.identifier.scopus2-s2.0-34548396248
dc.identifier.scopusqualityQ1
dc.identifier.startpage166en_US
dc.identifier.urihttps://doi.org/10.1016/j.jhazmat.2007.03.066
dc.identifier.urihttps://hdl.handle.net/11468/15650
dc.identifier.volume149en_US
dc.identifier.wosWOS:000250024000021
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherElsevier Science Bven_US
dc.relation.ispartofJournal of Hazardous Materials
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBacillus Subtilisen_US
dc.subjectPreconcentrationen_US
dc.subjectAmberlite Xad-4en_US
dc.subjectTrace Metalen_US
dc.subjectAtomic Absorption Spectrometryen_US
dc.titleThe use of Bacillus subtilis immobilized on Amberlite XAD-4 as a new biosorbent in trace metal determinationen_US
dc.titleThe use of Bacillus subtilis immobilized on Amberlite XAD-4 as a new biosorbent in trace metal determination
dc.typeArticleen_US

Dosyalar