dc.description.abstract | In this study, we assessed and compared the outcomes of two different fixation techniques for humeral diaphyseal fracture nonunions. A retrospective evaluation of 22 patients who underwent single-plate and double-plate fixation due to humeral diaphyseal nonunions was conducted. Union rates, union times, and functional outcomes of the patients were assessed. There was no significant difference between single-plate and double-plate fixation in terms of union rates or union times. The double-plate fixation group achieved significantly better functional outcomes. Nerve damage or surgical site infection were not encountered in either group.Due to its considerable effect on stability, double-plate fixation, offers both patients and surgeons confidence in terms of early adaptation to daily life in the postoperative period. | en_US |
dc.identifier.doi | 10.52628/88.4.02 | |
dc.identifier.endpage | 732 | en_US |
dc.identifier.issn | 0001-6462 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | 36800656 | |
dc.identifier.scopus | 2-s2.0-85148322426 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 727 | en_US |
dc.identifier.uri | https://doi.org/10.52628/88.4.02 | |
dc.identifier.uri | https://hdl.handle.net/11468/20052 | |
dc.identifier.volume | 88 | en_US |
dc.identifier.wos | WOS:000965062700008 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | en_US |
dc.publisher | Acta Medica Belgica | en_US |
dc.relation.ispartof | Acta Orthopaedica Belgica | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Humeral Nonunions | en_US |
dc.subject | Single Plate | en_US |
dc.subject | Double Plate | en_US |
dc.subject | Functional Results | en_US |
dc.title | The effect of single plate and double plate application on union and functional results in humeral diaphyseal nonunions | en_US |
dc.title | The effect of single plate and double plate application on union and functional results in humeral diaphyseal nonunions | |
dc.type | Article | en_US |