Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney

dc.authorid0000-0003-0642-6793en_US
dc.authorid0000-0003-4814-759Xen_US
dc.authorid0000-0002-2278-4729en_US
dc.contributor.authorBako, Derya
dc.contributor.authorKöksoy, Adem Yasin
dc.contributor.authorTurmak, Mehmet
dc.date.accessioned2023-08-04T08:31:32Z
dc.date.available2023-08-04T08:31:32Z
dc.date.issued2023en_US
dc.departmentDicle Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalıen_US
dc.description.abstractBackground Accurate estimation of kidney size and volume in the solitary functioning kidney is crucial because of a higher risk of developing kidney injury. MRI is an accurate method and is suitable for kidney volume measurement. Usually, axial axis images and measurement methods are preferred for kidney volume measurements. However, the anteroposterior diameter of the kidney is smaller than the longitudinal diameter, meaning that imaging in the coronal axis could provide needed information in a shorter time, enabling imaging of younger patients without sedation. Therefore, the purpose of this study was to compare coronal and axial axis kidney volume measurement methods and evaluate intra-observer and inter-observer reliability. Methods Axial axis T2W and coronal axis FIESTA images of kidneys were obtained with 10 mm slice thickness and no slice gap in pediatric patients with congenital solitary kidneys. Free-hand manual tracing was used to calculate volumes in both methods. Images were analyzed by two operators with diferent levels of experience. The expert operator computed solitary kidney volume twice in both methods for the intra-observer reliability, while the beginner operator’s measurements were used for the inter-observer reliability. Results High intra-observer (0.965 for axial and 0.972 for coronal) and inter-observer reliability were revealed (0.964 for axial and 0.963 for the coronal) for both measurement methods. Conclusion The coronal plane volume measurement method, which has a signifcantly shorter examination and post-processing time, is a highly reproducible and reliable method that can enable volume measurement with MRI in younger children, as the imaging time will be shortened.en_US
dc.identifier.citationBako, D., Köksoy, A. Y. ve Turmak, M. (2023). Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney. Pediatric Nephrology, 38(7), 2125-2130.en_US
dc.identifier.doi10.1007/s00467-022-05858-x
dc.identifier.endpage2130en_US
dc.identifier.issn0931-041X
dc.identifier.issn1432-198X
dc.identifier.issue7en_US
dc.identifier.pmid36547734
dc.identifier.scopus2-s2.0-85144684063
dc.identifier.scopusqualityQ1
dc.identifier.startpage2125en_US
dc.identifier.urifile:///C:/Users/Rojbin/Downloads/s00467-022-05858-x.pdf
dc.identifier.urihttps://hdl.handle.net/11468/12432
dc.identifier.volume38en_US
dc.identifier.wosWOS:000903162100002
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorTurmak, Mehmet
dc.language.isoenen_US
dc.publisherSpringer Science and Business Mediaen_US
dc.relation.ispartofPediatric Nephrology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectKidney volumeen_US
dc.subjectMRIen_US
dc.subjectPediatricen_US
dc.subjectSolitary functioning kidneyen_US
dc.titleComparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidneyen_US
dc.titleComparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Comparison of axial and coronal axis MRI kidney volume.pdf
Boyut:
831.05 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: