A portable device based on the interrupter technique for measuring airway resistance in preschool children

dc.contributor.authorDerman, O
dc.contributor.authorYaramis, A
dc.contributor.authorKirbas, G
dc.date.accessioned2024-04-24T17:33:11Z
dc.date.available2024-04-24T17:33:11Z
dc.date.issued2004
dc.departmentDicle Üniversitesien_US
dc.description.abstractThe interrupter technique for measuring airway resistance is a noninvasive method reported to require minimal subject cooperation. Therefore it has a good potential for use in young children who are not able to cooperate with conventional lung function tests. The interrupter method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equilibrates with mouth pressure. In order to investigate the compliance rate with the interrupter technique in preschool children and to look for associated baseline measures of RINT we performed a study in 214 children of ages from 3 months to 5 years. There was a significant inverse correlation between baserint and age (r = -0.672, p < 0.001), and standing height (r = -0.692, p < 0.001) in children with recurrent wheezing. However, this was not seen in healthy children. We concluded that the portable interrupter device is very useful in preschool children. The measurements showed that the a-e and standing height are inversely proportional to the baseline RINT values measured. We reported that these differences would be more apparent in children with a history of recurrent wheezing.en_US
dc.identifier.endpage126en_US
dc.identifier.issn1018-9068
dc.identifier.issue2en_US
dc.identifier.pmid15301301
dc.identifier.scopus2-s2.0-3342877702
dc.identifier.scopusqualityQ2
dc.identifier.startpage121en_US
dc.identifier.urihttps://hdl.handle.net/11468/20511
dc.identifier.volume14en_US
dc.identifier.wosWOS:000222875300005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherHogrefe & Huber Publishersen_US
dc.relation.ispartofJournal of Investigational Allergology and Clinical Immunology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAirway Resistanceen_US
dc.subjectChildrenen_US
dc.subjectLung Functionen_US
dc.subjectPreschoolen_US
dc.titleA portable device based on the interrupter technique for measuring airway resistance in preschool childrenen_US
dc.titleA portable device based on the interrupter technique for measuring airway resistance in preschool children
dc.typeArticleen_US

Dosyalar