Evaluation of Microleakage Caused by Different LED Light Sources in Composite Resins with AutoCAD Program
dc.contributor.author | Cangul, Suzan | |
dc.contributor.author | Atas, Osman | |
dc.contributor.author | Adiguzel, Ozkan | |
dc.contributor.author | Erpacal, Begum | |
dc.contributor.author | Bakir, Metin | |
dc.contributor.author | Eskibaglar, Mehmet | |
dc.date.accessioned | 2024-04-24T17:33:51Z | |
dc.date.available | 2024-04-24T17:33:51Z | |
dc.date.issued | 2020 | |
dc.department | Dicle Üniversitesi | en_US |
dc.description.abstract | OBJECTIVE: To use AutoCAD software to examine the microleakage of bulk-fill composites occurring as a result of polymerization with different light sources. STUDY DESIGN: In a total of 40 extracted first molar teeth, class I cavities were opened. Then 4 groups were formed of 10 samples in each group. All the samples were restored with SDR bulk-fill composite. The samples were polymerized with an LED light source as follows: Group 1, Mikado; Group 2, Woodpecker; Group 3, Planmeca; and Group 4, CarboLED. Each tooth was divided into 2 sections. Each section was examined under stereomicroscope, and the dimensions of the leakage surface area were measured with AutoCAD software. In the statistical evaluations of the data, the Kruskal-Wallis and Tukey B tests were used. RESULTS: Significant differences were found between the groups in the statistical evaluations (p <0.05). The highest value was found in the CarboLED group and the lowest value was found in the group where Mikado light source was used. CONCLUSION: There are many factors affecting polymerization. Since there are insufficient studies on this subject, it should be supported with new research. | en_US |
dc.identifier.endpage | 138 | en_US |
dc.identifier.issn | 0884-6812 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.scopus | 2-s2.0-85179820667 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 133 | en_US |
dc.identifier.uri | https://hdl.handle.net/11468/20868 | |
dc.identifier.volume | 42 | en_US |
dc.identifier.wos | WOS:000592246800005 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | en_US |
dc.publisher | Sci Printers & Publ Inc | en_US |
dc.relation.ispartof | Analytical and Quantitative Cytopathology and Histopathology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Autocad | en_US |
dc.subject | Bulkfill Composite | en_US |
dc.subject | Micro-Leakage | en_US |
dc.subject | Stereomicroscope | en_US |
dc.title | Evaluation of Microleakage Caused by Different LED Light Sources in Composite Resins with AutoCAD Program | en_US |
dc.title | Evaluation of Microleakage Caused by Different LED Light Sources in Composite Resins with AutoCAD Program | |
dc.type | Article | en_US |