The similarities and differences between liquid-based and conventional methods in evaluation of thyroid fine needle aspiration cytologies

dc.authorid0000-0002-0645-8755en_US
dc.contributor.authorÖzer, Mehmet
dc.contributor.authorÖzekinci, Selver
dc.date.accessioned2023-10-18T11:03:24Z
dc.date.available2023-10-18T11:03:24Z
dc.date.issued2023en_US
dc.departmentDicle Üniversitesi, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü, Tıbbi Patoloji Ana Bilim Dalıen_US
dc.description.abstractAims: Thyroid nodules are one of the most frequent medical issues in endocrinology in our country and around the world. The appropriate evaluation of the nodule is critical in the management of patients. Fine needle aspiration cytology (FNAC) is one of the most accurate tools for evaluating these nodules. Conventional and liquid-based (LB) methods are available for thyroid FNAC. In this paper, we aim to determine the best cytological method for the evaluation of thyroid fine needle aspiration materials. Settings and Design: Fine needle aspiration (FNA) materials obtained and prepared by conventional and LB methods from 310 patients were evaluated. These slides were compared in terms of 12 cytological parameters in a three-tiered system, and the kappa coefficient was calculated. Methods and Material: Two slides were prepared from FNA samples, and the rest of the material was left in protective solution for LB cytology. Surepath was used as a LB technique. Conventional slides (CS) were left to dry in the air and stained with May Grunwald Giemsa. Slides prepared by two different techniques were compared in 12 cytomorphological parameters, and Kappa coefficients and correlations were calculated. Statistical Analysis Used: Kappa statistics. Results: In comparison of LB and CS, the highest kappa coefficient was in chromatin texture (κ:0.738) and inflammatory cells (κ: 0.482). On other parameters, fair or poor agreement was observed. Conclusions: Although there are some superiorities to LB cytology, co-application of these two methods is more favorable in thyroid fine needle aspiration.en_US
dc.identifier.citationÖzer, M. ve Özekinci, S. (2023). The similarities and differences between liquid-based and conventional methods in evaluation of thyroid fine needle aspiration cytologies. Journal of Cytology, 40(3), 140-144.en_US
dc.identifier.doi10.4103/joc.joc_27_23
dc.identifier.endpage144en_US
dc.identifier.issn0970-9371
dc.identifier.issue3en_US
dc.identifier.pmid37745811
dc.identifier.scopus2-s2.0-85171436257
dc.identifier.scopusqualityQ3
dc.identifier.startpage140en_US
dc.identifier.urihttps://journals.lww.com/jocy/fulltext/2023/40030/the_similarities_and_differences_between.6.aspx
dc.identifier.urihttps://hdl.handle.net/11468/12857
dc.identifier.volume40en_US
dc.identifier.wosWOS:001106647500006
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.institutionauthorÖzekinci, Selver
dc.language.isoenen_US
dc.publisherWolters Kluwer Medknow Publicationsen_US
dc.relation.ispartofJournal of Cytology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCytological techniquesen_US
dc.subjectFine needle aspirationen_US
dc.subjectThyroiden_US
dc.titleThe similarities and differences between liquid-based and conventional methods in evaluation of thyroid fine needle aspiration cytologiesen_US
dc.titleThe similarities and differences between liquid-based and conventional methods in evaluation of thyroid fine needle aspiration cytologies
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
The similarities and differences between liquid-based and conventional methods in evaluation of thyroid fine needle aspiration cytologies.pdf
Boyut:
903.6 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: