Biomechanical and biochemical evaluation of the effect of systemic application of omeprazole on the osseointegration of titanium implants

dc.authorid0000-0001-7160-1899en_US
dc.contributor.authorTekin, Samet
dc.contributor.authorDündar, Serkan
dc.contributor.authorDemirci, Fatih
dc.contributor.authorBozoğlan, Alihan
dc.contributor.authorYıldırım, Tuba Talo
dc.contributor.authorGüneş, Nedim
dc.contributor.authorAcıkan, Izzet
dc.contributor.authorÖzcan, Erhan Cahit
dc.date.accessioned2021-04-29T11:37:29Z
dc.date.available2021-04-29T11:37:29Z
dc.date.issued2021en_US
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Ağız-Diş-Çene Hastalıkları ve Cerrahisi Bölümüen_US
dc.descriptionWOS:000639043100001
dc.descriptionPMID: 33843027
dc.description.abstractBackground This study aimed to investigate the effects of systemic omeprazole treatment on the osseointegration of titanium implants. Material and methods After surgical insertion of titanium implants into the metaphyseal part of rats' both right and left tibial bones, the animals were randomly divided into three equal groups: control (n = 8), omeprazole dosage-1 (n = 8) (OME-1), and omeprazole dosage-2 (n = 8) (OME-2) and totally 48 implants were surgically integrated. The rats in the control group received no treatment during the four-week postoperative experimental period. In the OME-1 and OME-2 groups, the rats received omeprazole in doses of 5 and 10 mg/kg, respectively, every 3 days for 4 weeks. After the experimental period, the rats were euthanized. One rat died in each group and the study was completed with seven rats in each group. Blood serum was collected for biochemical analysis, and the implants and surrounding bone tissue were used for biomechanical reverse-torque analysis. In the biomechanical analysis, implants that were not properly placed and were not osseointegrated were excluded from the evaluation. Results One-way analysis of variance and Tukey's honestly significant difference test and Student's t test were used for statistical analysis. The reverse-torque test (control (n = 9), OME-1 (N = 7), and OME-2 (n = 7)) analysis of biochemical parameters (alkaline phosphatase, calcium, phosphorus, aspartate aminotransferase, alanine amino transferase, urea, and creatinine) revealed no significant differences between the groups (control (n = 7), OME-1 (N = 7), and OME-2 (n = 7)) (P > 0.05). Conclusions Omeprazole had no biomechanical or biochemical effects on the osseointegration process of titanium implants.en_US
dc.identifier.citationTekin, S., Dündar, S., Demirci, F., Bozoğlan, A., Yıldırım, T.T., Güneş, N. ve diğerleri. (2021). Biomechanical and biochemical evaluation of the effect of systemic application of omeprazole on the osseointegration of titanium implants. International Journal of Implant Dentistry, 7(1)en_US
dc.identifier.doi10.1186/s40729-021-00310-5
dc.identifier.issn2198-4034
dc.identifier.issue1en_US
dc.identifier.pmid33843027
dc.identifier.urihttps://journalimplantdent.springeropen.com/track/pdf/10.1186/s40729-021-00310-5.pdf
dc.identifier.urihttps://hdl.handle.net/11468/6826
dc.identifier.volume7en_US
dc.identifier.wosWOS:000639043100001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.institutionauthorGüneş, Nedim
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofInternational Journal of Implant Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectOsseointegrationen_US
dc.subjectProton pump inhibitorsen_US
dc.subjectOmeprazoleen_US
dc.subjectBone implant connectionen_US
dc.subjectBone implant contacten_US
dc.titleBiomechanical and biochemical evaluation of the effect of systemic application of omeprazole on the osseointegration of titanium implantsen_US
dc.titleBiomechanical and biochemical evaluation of the effect of systemic application of omeprazole on the osseointegration of titanium implants
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Biomechanical and biochemical evaluation.pdf
Boyut:
719.96 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: