Pharmacomechanical thrombolysis with a rotator thrombolysis device in iliofemoral deep venous thrombosis

dc.contributor.authorKarahan, Oguz
dc.contributor.authorKutas, H. Baris
dc.contributor.authorGurbuz, Orcun
dc.contributor.authorTezcan, Orhan
dc.contributor.authorCaliskan, Ahmet
dc.contributor.authorYavuz, Celal
dc.contributor.authorDemirtas, Sinan
dc.date.accessioned2024-04-24T17:14:44Z
dc.date.available2024-04-24T17:14:44Z
dc.date.issued2016
dc.departmentDicle Üniversitesien_US
dc.description.abstractObjective Deep venous thrombosis (DVT) is a life-threatening and morbid pathology. This study aimed to investigate the efficacy of an early thrombolysis procedure using a rotator thrombolysis device. Methods Sixty-seven patients with acute proximal DVT were enrolled in the study. Patients' data were recorded retrospectively. Initially, an infrarenal retrievable vena cava filter was placed through the femoral vein. Then, a rotator thrombolysis device and a thrombolytic agent injection were applied to the occluded segments of the deep veins by puncturing the popliteal vein. Results The identified reasons were trauma (43.3%), pregnancy (20.9%), undiagnosed (11.9%), major surgical operation (10.5%), immobilization (7.5%), and malignancy (5.9%). Immediate total recanalization was conducted in all patients, and the leg diameters returned to normal ranges in the early postoperative period. Hospital mortality or severe complications were not detected. Conclusion New thrombolytic devices seem to reduce in-hospital mortality risks and may potentially decrease post-thrombotic morbidity.en_US
dc.identifier.doi10.1177/1708538115612637
dc.identifier.endpage486en_US
dc.identifier.issn1708-5381
dc.identifier.issn1708-539X
dc.identifier.issue5en_US
dc.identifier.pmid26490390
dc.identifier.scopus2-s2.0-84987909406
dc.identifier.scopusqualityQ2
dc.identifier.startpage481en_US
dc.identifier.urihttps://doi.org/10.1177/1708538115612637
dc.identifier.urihttps://hdl.handle.net/11468/18170
dc.identifier.volume24en_US
dc.identifier.wosWOS:000383394000005
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.ispartofVascular
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectDeep Venous Thrombosisen_US
dc.subjectRotator Thrombolytic Deviceen_US
dc.subjectTreatmenten_US
dc.subjectOutcomesen_US
dc.titlePharmacomechanical thrombolysis with a rotator thrombolysis device in iliofemoral deep venous thrombosisen_US
dc.titlePharmacomechanical thrombolysis with a rotator thrombolysis device in iliofemoral deep venous thrombosis
dc.typeArticleen_US

Dosyalar