A comparison of postoperative complications following cardiac implantable electronic device procedures in patients treated with antithrombotic drugs
dc.authorid | 0000-0002-9049-7123 | en_US |
dc.authorid | 0000-0003-2243-6190 | en_US |
dc.authorid | 0000-0002-1992-7848 | en_US |
dc.authorid | 0000-0001-9407-4155 | en_US |
dc.authorid | 0000-0001-6453-9310 | en_US |
dc.authorid | 0000-0001-6608-871X | en_US |
dc.authorid | 0000-0001-7317-2979 | en_US |
dc.contributor.author | Demir, Muhammed | |
dc.contributor.author | Özbek, Mehmet | |
dc.contributor.author | Polat, Nihat | |
dc.contributor.author | Aktan, Adem | |
dc.contributor.author | Yıldırım, Bünyamin | |
dc.contributor.author | Argun, Lokman | |
dc.contributor.author | İldırımlı, Kamran | |
dc.contributor.author | Toprak, Nizamettin | |
dc.date.accessioned | 2023-04-24T13:04:58Z | |
dc.date.available | 2023-04-24T13:04:58Z | |
dc.date.issued | 2022 | en_US |
dc.department | Dicle Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Kardiyoloji Ana Bilim Dalı | en_US |
dc.description.abstract | Background The incidence of postoperative complications following cardiac implantable electronic device (CIED) procedures in patients treated with antithrombotic drugs has not been studied sufficiently. Here we present a comparison of complications after CIED implantations. Methods Using an observational study design, the study included 1807 patients with a taking antiplatelet drugs (n: 1601), nonvitamin K anticoagulants (NOAC) (n: 136), and warfarin (n: 70) undergoing CIED surgery. Primary endpoint was accepted as cumulative events including composite of clinically significant hematoma (CSH), pericardial effusion or tamponade, pneumothorax, and infection related to device system. Secondary outcomes included each compenent of cumulative events. Multivariable analysis was performed to identify predictors of cumulative events. Results The overall cumulative event rate was 3.7% (67 of 1807). Cumulative events occured 3.1% (50 of 1601) in the antiplatelet, 5.1% (7 of 136) NOAC, and 14.3% (10 of 70) warfarin groups (p < 0.001). CSH occurred in 2 of 70 patients (2.9%) in the warfarin group, as compared with 5 of 1601 (0.3%) in the antiplatelet group (p: 0.032). However, no significant differences were found between NOAC and warfarin groups in terms of CSH (0.7% vs. 2.9% respectively, p: 0.267). Warfarin treatment was an independent predictor of cumulative events and increased 2.9-fold the risk of cumulative events. Major surgical complications were rare and did not differ significantly between the study groups. Conclusions The incidence and severity of complications may be lower in patients treated with periprocedurally antiplatelet or NOAC therapy when compared with warfarin therapy. Further randomized control studies are required to confirm our findings | en_US |
dc.identifier.citation | Demir, M., Özbek, M., Polat, N., Aktan, A., Yıldırım, B., Argun, L. ve diğerleri. (2022). A comparison of postoperative complications following cardiac implantable electronic device procedures in patients treated with antithrombotic drugs. Pace-Pacing and Clinical Electrophysiology, 45(6), 733-741. | en_US |
dc.identifier.doi | 10.1111/pace.14517 | |
dc.identifier.endpage | 741 | en_US |
dc.identifier.issn | 0147-8389 | |
dc.identifier.issn | 1540-8159 | |
dc.identifier.issue | 6 | en_US |
dc.identifier.pmid | 35527396 | |
dc.identifier.scopus | 2-s2.0-85130277105 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 733 | en_US |
dc.identifier.uri | https://onlinelibrary.wiley.com/doi/epdf/10.1111/pace.14517 | |
dc.identifier.uri | https://hdl.handle.net/11468/11737 | |
dc.identifier.volume | 45 | en_US |
dc.identifier.wos | WOS:000796898900001 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.institutionauthor | Demir, Muhammed | |
dc.institutionauthor | Özbek, Mehmet | |
dc.institutionauthor | Polat, Nihat | |
dc.institutionauthor | Yıldırım, Bünyamin | |
dc.institutionauthor | Argun, Lokman | |
dc.institutionauthor | İldırımlı, Kamran | |
dc.institutionauthor | Toprak, Nizamettin | |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.ispartof | Pace-Pacing and Clinical Electrophysiology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Anticoagulants | en_US |
dc.subject | Bleedings | en_US |
dc.subject | Complications | en_US |
dc.subject | Pacemakers | en_US |
dc.subject | Perioperative | en_US |
dc.title | A comparison of postoperative complications following cardiac implantable electronic device procedures in patients treated with antithrombotic drugs | en_US |
dc.title | A comparison of postoperative complications following cardiac implantable electronic device procedures in patients treated with antithrombotic drugs | |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- A comparison of postoperative complications following cardiac implantable.pdf
- Boyut:
- 588.41 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası
Lisans paketi
1 - 1 / 1
[ X ]
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: