Minimally invasive plate osteosynthesis in open pediatric tibial fractures

dc.contributor.authorÖzkul, Emin
dc.contributor.authorGem, Mehmet
dc.contributor.authorArslan, Hüseyin
dc.contributor.authorAlemdar, Celil
dc.contributor.authorAzboy, İbrahim
dc.contributor.authorArslan, Seher Gündüz
dc.date.accessioned2024-04-24T17:56:23Z
dc.date.available2024-04-24T17:56:23Z
dc.date.issued2016
dc.departmentDicle Üniversitesien_US
dc.description.abstractObjectives: The aim of this study is to investigate the effectiveness and reliability of limited-contact locking plates in minimally invasive percutaneous osteosynthesis (MIPO) of the lateral tibia. Design: A retrospective study. Patients and Methods: The retrospective study included 14 patients who were operatively treated with an MIPO technique due to open tibial fractures between 2006 and 2012. The patients were 11 males and 3 females with a mean age of 13.2 (range, 9 to 16) years. The patients were followed up for a mean period of 2.4 (range, 1 to 5) years. The mechanism of the injuries included a motor vehicle accident (n=11), a shotgun injury (n=2), and a fall from height (n=1). According to the Gustilo-Anderson classification, 10 patients had type I (72%), 2 had type II (14%), and 2 had type III (14%) open fractures. Results: The mean time to radiologic union was 18 (range, 11 to 32) weeks. No infection was detected that would require implant removal. No complications such as early epiphyseal closure, angulation, or limb-length inequality were observed. Conclusions: Limited-contact locking plates in MIPO of the lateral tibia is an effective alternative method in the treatment of open pediatric tibial fractures.en_US
dc.identifier.citationÖzkul, E., Gem, M., Arslan, H., Alemdar, C., Azboy, İ. ve Arslan, S. G. (2016). Minimally invasive plate osteosynthesis in open pediatric tibial fractures. Journal of Pediatric Orthopaedics, 36(4), 416-422.
dc.identifier.doi10.1097/BPO.0000000000000451
dc.identifier.endpage422en_US
dc.identifier.issn0271-6798
dc.identifier.issue4en_US
dc.identifier.pmid25851671en_US
dc.identifier.scopus2-s2.0-84969939786en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage416en_US
dc.identifier.urihttps://doi.org/10.1097/BPO.0000000000000451
dc.identifier.urihttps://hdl.handle.net/11468/23485
dc.identifier.urihttps://journals.lww.com/pedorthopaedics/fulltext/2016/06000/minimally_invasive_plate_osteosynthesis_in_open.17.aspx
dc.identifier.volume36en_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherLippincott Williams and Wilkinsen_US
dc.relation.ispartofJournal of Pediatric Orthopaedicsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOpen fractureen_US
dc.subjectOsteosynthesis with platingen_US
dc.subjectPediatric tibiaen_US
dc.titleMinimally invasive plate osteosynthesis in open pediatric tibial fracturesen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures.pdf
Boyut:
273.59 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası