Removal of Broken Hemodialysis Catheter from Subclavian Vein via Snare Under Fluoroscopy

dc.contributor.authorGulclu, Orkut
dc.contributor.authorYavuz, Celal
dc.contributor.authorDemirtas, Sinan
dc.contributor.authorCaliskan, Ahmet
dc.contributor.authorYazici, Suleyman
dc.contributor.authorKarahan, Oguz
dc.contributor.authorMavitas, Binali
dc.date.accessioned2024-04-24T17:27:33Z
dc.date.available2024-04-24T17:27:33Z
dc.date.issued2014
dc.departmentDicle Üniversitesien_US
dc.description.abstractVenous access with a central catheter is typically a necessary technique for hemodialysis. Although, central venous catheters are widely used, they may cause life-threatening complications by migration of fractured catheter pieces. Thus, venous catheters should be controlled routinely by medical staff or the patients themselves. In this paper we report a case of a fractured catheter with vena cava migration in which there were no symptoms and describe the non-surgical retrieval of the migrated catheter by snare technique.en_US
dc.identifier.doi10.5262/tndt.2014.1001.16
dc.identifier.endpage76en_US
dc.identifier.issn1300-7718
dc.identifier.issue1en_US
dc.identifier.startpage73en_US
dc.identifier.trdizinid161384
dc.identifier.urihttps://doi.org/10.5262/tndt.2014.1001.16
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/161384
dc.identifier.urihttps://hdl.handle.net/11468/20051
dc.identifier.volume23en_US
dc.identifier.wosWOS:000217183500016
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakTR-Dizin
dc.language.isoenen_US
dc.publisherTurk Nefroloji Diyaliz Transplantasyon Dergisien_US
dc.relation.ispartofTurkish Nephrology Dialysis and Transplantation Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBroken Catheteren_US
dc.subjectSnare Techniqueen_US
dc.subjectFluoroscopyen_US
dc.titleRemoval of Broken Hemodialysis Catheter from Subclavian Vein via Snare Under Fluoroscopyen_US
dc.titleRemoval of Broken Hemodialysis Catheter from Subclavian Vein via Snare Under Fluoroscopy
dc.typeArticleen_US

Dosyalar