CT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques
dc.authorid | 0000-0002-9586-2425 | en_US |
dc.authorid | 0000-0001-8030-6795 | en_US |
dc.authorid | 0000-0002-7224-7737 | en_US |
dc.authorid | 0000-0003-4164-3611 | en_US |
dc.authorid | 0000-0001-5986-5293 | en_US |
dc.contributor.author | Deniz, Muhammed Akif | |
dc.contributor.author | Çakır, Çağlayan | |
dc.contributor.author | Kılınç, Fatih | |
dc.contributor.author | Kurt, Osman | |
dc.contributor.author | Deniz, Zelal Taş | |
dc.date.accessioned | 2024-05-02T12:05:10Z | |
dc.date.available | 2024-05-02T12:05:10Z | |
dc.date.issued | 2022 | en_US |
dc.department | Dicle Üniversitesi, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümü, Radyoloji Ana Bilim Dalı | en_US |
dc.description.abstract | Objective: We aimed to evaluate the diagnostic accuracy and complication rates of computed tomography (CT)-guided core needle biopsy and fine needle aspiration biopsy (FNAB). Materials and Methods: Patients who underwent CT-guided lung mass biopsy were included. The patients were evaluated in terms of age, gender, lesion diameter, lesion localization, depth of the mass, type of biopsy procedure (core needle biopsies and FNAB). Results: The accuracy rate of FNAB in diagnostic material was found to be 100% in terms of benign, malignant and all lesions. The specificity and sensitivity of FNAB was found to be 100%. The diagnostic accuracy rate of core needle biopsy was found to be 70% in benign lesions, 100% in malignant lesions. The specificity of core needle biopsy was 90% and sensitivity 100%. There was no statistically significant difference between the two biopsy techniques in terms of complications. Conclusion: In conclusion, we found that the diagnostic rates of FNAB and core needle biopsy were close in malignant lesions, the diagnostic rate of core needle biopsy was higher in benign lesions, and there was no difference in terms of complications in both biopsy techniques. | en_US |
dc.identifier.citation | Deniz, M. A., Çakır, Ç., Kılınç, F., Kurt, O. ve Deniz, Z. T. (2022). CT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques. Marmara Medical Journal, 35(2), 219-224. | en_US |
dc.identifier.endpage | 224 | en_US |
dc.identifier.issn | 1019-1941 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-85131804769 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 219 | en_US |
dc.identifier.uri | https://dergipark.org.tr/en/pub/marumj/issue/69333/1120552 | |
dc.identifier.uri | https://hdl.handle.net/11468/28639 | |
dc.identifier.volume | 35 | en_US |
dc.identifier.wos | WOS:000806472400016 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.institutionauthor | Deniz, Muhammed Akif | |
dc.language.iso | en | en_US |
dc.publisher | Marmara University | en_US |
dc.relation.ispartof | Marmara Medical Journal | |
dc.relation.isversionof | 10.5472/marumj.1120552 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Computed tomography | en_US |
dc.subject | Lung | en_US |
dc.subject | Mass | en_US |
dc.subject | Transthoracic biopsy | en_US |
dc.title | CT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques | en_US |
dc.title | CT-guided lung biopsy: diagnostic accuracy and complication rates of biopsy techniques | |
dc.type | Article | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- CT-guided lung biopsy diagnostic accuracy and complication rates of biopsy techniques.pdf
- Boyut:
- 435.48 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Makale Dosyası
Lisans paketi
1 - 1 / 1
[ X ]
- İsim:
- license.txt
- Boyut:
- 1.44 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: