Load Frequency Control of Single-Area Power System with PI-PD Controller Design for Performance Improvement
dc.contributor.author | Guler, Yavuz | |
dc.contributor.author | Kaya, Ibrahim | |
dc.date.accessioned | 2024-04-24T16:10:40Z | |
dc.date.available | 2024-04-24T16:10:40Z | |
dc.date.issued | 2023 | |
dc.department | Dicle Üniversitesi | en_US |
dc.description.abstract | Load frequency control (LFC) is an important control problem as it determines the quality of power generation by controlling the system frequency and inter-area tie-line power. To maintain a good quality power supply, LFC must be robust against unknown external disturbances and parameter variations of the power system. Therefore, this paper presents the design of PI-PD controllers, which are robust against parameter changes and have good disturbance suppression capability, for load frequency control of a single-area single- or multi-source power system. PI-PD controller parameters were obtained by applying the weighted geometric center method to the stability boundary locus of the closed-loop control system. The approach was applied to both the inner and outer loops of the PI-PD control system structure, sequentially. Performance and robustness of the proposed PI-PD control system are evaluated using some well-known integral error criteria values, settling time, and peak value (overshoot) in the analysis of the power system with both nominal values and & PLUSMN; 50% changes in the system parameters. The simulation results show that the designed PI-PD controller effectively limits the effect of load disturbance and variations in system parameters. | en_US |
dc.identifier.doi | 10.1007/s42835-022-01371-1 | |
dc.identifier.endpage | 2648 | en_US |
dc.identifier.issn | 1975-0102 | |
dc.identifier.issn | 2093-7423 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.scopus | 2-s2.0-85146058963 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 2633 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s42835-022-01371-1 | |
dc.identifier.uri | https://hdl.handle.net/11468/15016 | |
dc.identifier.volume | 18 | en_US |
dc.identifier.wos | WOS:000912289200003 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | en_US |
dc.publisher | Springer Singapore Pte Ltd | en_US |
dc.relation.ispartof | Journal of Electrical Engineering & Technology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Load Frequency Control | en_US |
dc.subject | Pi-Pd | en_US |
dc.subject | Stability Boundary Locus | en_US |
dc.subject | Wgc Method | en_US |
dc.title | Load Frequency Control of Single-Area Power System with PI-PD Controller Design for Performance Improvement | en_US |
dc.title | Load Frequency Control of Single-Area Power System with PI-PD Controller Design for Performance Improvement | |
dc.type | Article | en_US |