Minimally Invasive Plate Osteosynthesis in Open Pediatric Tibial Fractures
[ X ]
Tarih
2016
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Lippincott Williams & Wilkins
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Objectives: The aim of this study is to investigate the effectiveness and reliability of limited-contact locking plates in minimally invasive percutaneous osteosynthesis (MIPO) of the lateral tibia. Design: A retrospective study. Patients and Methods: The retrospective study included 14 patients who were operatively treated with an MIPO technique due to open tibial fractures between 2006 and 2012. The patients were 11 males and 3 females with a mean age of 13.2 (range, 9 to 16) years. The patients were followed up for a mean period of 2.4 (range, 1 to 5) years. The mechanism of the injuries included a motor vehicle accident (n=11), a shotgun injury (n=2), and a fall from height (n=1). According to the Gustilo-Anderson classification, 10 patients had type I (72%), 2 had type II (14%), and 2 had type III (14%) open fractures. Results: The mean time to radiologic union was 18 (range, 11 to 32) weeks. No infection was detected that would require implant removal. No complications such as early epiphyseal closure, angulation, or limb-length inequality were observed. Conclusions: Limited-contact locking plates in MIPO of the lateral tibia is an effective alternative method in the treatment of open pediatric tibial fractures.
Açıklama
Anahtar Kelimeler
Pediatric Tibia, Open Fracture, Osteosynthesis With Plating
Kaynak
Journal of Pediatric Orthopaedics
WoS Q Değeri
Q2
Scopus Q Değeri
Cilt
36
Sayı
4