Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants

dc.contributor.authorÖzcan, Erhan Cahit
dc.contributor.authorGül, Mehmet
dc.contributor.authorDündar, Serkan
dc.contributor.authorBozoğlan, Alihan
dc.contributor.authorKarasu, Necmettin
dc.contributor.authorBal, Ali
dc.contributor.authorGüneş, Nedim
dc.contributor.authorBingül, Muhammet Bahattin
dc.date.accessioned2022-03-18T06:59:13Z
dc.date.available2022-03-18T06:59:13Z
dc.date.issued2021en_US
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Ağız-Diş-Çene Hastalıkları ve Cerrahisi Bölümüen_US
dc.description.abstractAbstract Objective Researchs of the effects of ankaferd blood stopper (ABS) on bone healing metabolism have revealed that it affects bone regeneration positively. The exact mechanism by which this positive effect on bone tissue metabolism is not known. The aim of this study is to biomechanic and biochemical analysis of the effects of the local ABS application on osseointegration of 3 different surfaced titanium implants. Material & Methods Spraque dawley rats were divided machined surfaced (MS) (n ​= ​10), sandblasted and large acid grid (SLA) (n ​= ​10) and resorbable blast material (RBM) (n ​= ​10) surfaced implants. ABS applied locally during the surgical application of the titanium implant before insertion in bone sockets. After 4 weeks experimental period the rats sacrificed and implants with surrounding bone tissues were removed to reverse torque analysis (Newton), blood samples collected to biochemical analysis (ALP, calcium, P) Results Biomechanic bone implant contact ratio detected higher in SLA surfaced implants compared with the RBM and controls (P ​< ​0,05). Phosphor levels detected lower in RBM implant group compared with the controls and SLA (P ​< ​0,05). Additionally; phosphor levels detected highly in controls compared with the RBM implants. Conclusion According the biomechanical parameters ABS may be more effective in SLA and RBM surfaced implants when locally applied.en_US
dc.identifier.citationÖzcan, E. C., Gül, M., Dündar, S., Bozoğlan, A., Karasu, N., Bal, A. ve diğerleri. (2021). Effects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants. Journal of Oral Biology and Craniofacial Research, 11(4), 524-528.en_US
dc.identifier.doi10.1016/j.jobcr.2021.07.008
dc.identifier.endpage528en_US
dc.identifier.issn2212-4268
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85110671469
dc.identifier.scopusqualityQ1
dc.identifier.startpage524en_US
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S2212426821000774?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/11468/9454
dc.identifier.volume11en_US
dc.indekslendigikaynakScopus
dc.institutionauthorGüneş, Nedim
dc.language.isoenen_US
dc.publisherElsevier B.V.en_US
dc.relation.ispartofJournal of Oral Biology and Craniofacial Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnkaferd blood stopperen_US
dc.subjectBiomechanicen_US
dc.subjectBone implant contacten_US
dc.subjectImplant surfacesen_US
dc.subjectOsseintegrationen_US
dc.titleEffects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implantsen_US
dc.titleEffects of local application of the ankaferd blood stopper on osseointegration in three different surface titanium implants
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Effects of local application of the ankaferd blood stopper on.pdf
Boyut:
1006.84 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: