An analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systems

dc.contributor.authorDevecioglu, Atilla G.
dc.contributor.authorOruc, Vedat
dc.date.accessioned2024-04-24T16:18:32Z
dc.date.available2024-04-24T16:18:32Z
dc.date.issued2017
dc.departmentDicle Üniversitesien_US
dc.description.abstractThe results of an analysis are discussed in this paper considering R1234yf, R444A and R445A refrigerants having low Global Warming Potential (GWP) which can be used in the mobile air conditioning systems. The evaporation temperatures of -5 degrees C and +5 degrees C while condenser temperatures of 30 degrees C and 60 degrees C were taken for the evaluations of thermodynamic properties of the refrigerants. In the study, electrical power consumption of the system and COP values were calculated considering thermodynamic properties determined for the points in the cycle depending on the assumed system parameters. The system was considered to operate in a steady-state cycle. The pressure loss through evaporator and condenser, and heat transfer amounts through connecting tubes, expansion valve and compressor were neglected for the computations. The computations have pointed out that while cooling capacity of R444A and R445A were higher; their COP values were smaller compared to R1234yf because of their increased consumption of electricity. Although COP of R444A is smaller compared to R1234yf, it may be suggested that R444A can be utilized in air-conditioning systems of heavy vehicles such as busses, trucks, and trains due to its decreased flammability risk by mixture content. (C) 2017 Elsevier Ltd. All rights reserved.en_US
dc.identifier.doi10.1016/j.tsep.2017.02.002
dc.identifier.endpage5en_US
dc.identifier.issn2451-9049
dc.identifier.scopus2-s2.0-85026869665
dc.identifier.scopusqualityQ1
dc.identifier.startpage1en_US
dc.identifier.urihttps://doi.org/10.1016/j.tsep.2017.02.002
dc.identifier.urihttps://hdl.handle.net/11468/16159
dc.identifier.volume1en_US
dc.identifier.wosWOS:000620784900002
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofThermal Science and Engineering Progress
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMac Systemsen_US
dc.subjectAlternative Refrigeranten_US
dc.subjectFlammabilityen_US
dc.subjectCopen_US
dc.subjectIsentropic Efficiencyen_US
dc.titleAn analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systemsen_US
dc.titleAn analysis on the comparison of low-GWP refrigerants to alternatively use in mobile air-conditioning systems
dc.typeArticleen_US

Dosyalar