An 8 month clinical trial of bond failues with four different types of orthodontic adhesives

dc.contributor.authorBaşaran, Güvenç
dc.contributor.authorÖzer, Törün
dc.contributor.authorHamamcı, Orhan
dc.date.accessioned2024-04-24T17:56:20Z
dc.date.available2024-04-24T17:56:20Z
dc.date.issued2006
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Ortodonti Ana Bilim Dalıen_US
dc.description.abstractIn this study the bonding survival of total etching and self etching composite resins (Rely-a-Bond, Kurasper F, Ideal 1, Prompt L pomp with Transbond XT) for orthodontic purposes were compared. A sample of 20 patients were treated with fixed appliances. The treatment group consisted of 10 girls and 10 boys who were 16–19 years old. A split mouth technique was used. The patients were followed for a period of 8 months. Bond failures were recorded in each patient's special record, with the time of bond failure identified as the date when bond failure was noticed. Bond failure rates and the corresponding bracket survival curves were plotted using the Kaplan-Meier product limit estimate. Bracket survival distributions were then compared with a student t test. The type of the bonding agent did not influence the bracket survival rate significantly (p >.05). In conclusion, Self etching primers could be used as an alternative to conventional etching adhesive systems.en_US
dc.identifier.citationBaşaran, G., Özer, T. ve Hamamcı, O. (2006). An 8 month clinical trial of bond failues with four different types of orthodontic adhesives. Biotechnology and Biotechnological Equipment, 20(1), 163-168.
dc.identifier.doi10.1080/13102818.2006.10817324
dc.identifier.endpage168en_US
dc.identifier.issn1310-2818
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-31944437732
dc.identifier.scopusqualityQ3
dc.identifier.startpage163en_US
dc.identifier.urihttps://doi.org/10.1080/13102818.2006.10817324
dc.identifier.urihttps://hdl.handle.net/11468/23453
dc.identifier.urihttps://www.tandfonline.com/doi/abs/10.1080/13102818.2006.10817324
dc.identifier.volume20en_US
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.relation.ispartofBiotechnology and Biotechnological Equipment
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleAn 8 month clinical trial of bond failues with four different types of orthodontic adhesivesen_US
dc.titleAn 8 month clinical trial of bond failues with four different types of orthodontic adhesives
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
An 8 Month Clinical Trial of Bond Failues with Four Different Types of Orthodontic Adhesives.pdf
Boyut:
237.41 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası