Comparison of Different Methods for Measurement of Intraocular Pressure and Evaluation of Effect of Central Corneal Thickness on Measurement Results

dc.contributor.authorSakalar, Yildirim Bayezit
dc.contributor.authorKeklikci, Ugur
dc.contributor.authorBalsak, Selahattin
dc.contributor.authorDogan, Eyyup
dc.contributor.authorUnlu, Kaan
dc.date.accessioned2024-04-24T17:24:30Z
dc.date.available2024-04-24T17:24:30Z
dc.date.issued2010
dc.departmentDicle Üniversitesien_US
dc.description.abstractPurpose: To compare measurements of intraocular pressure (IOP) by Goldmann applanation tonometer ( GAT), tonopen and non-contact tonometer (NCT) in normal eyes, and determine the relationship between the results of IOP measurement and central corneal thickness (CCT). Material and Method: Seventy-nine eyes of 41 patients, whose ophthalmologic examination and visual field test revealed no glaucoma, were included into the study. IOP was measured by GAT, NCT and tonopen. CCT was measured with an ultrasonic pachymeter. Results: The mean IOP measured by GAT was 12.63 +/- 2.94 mmHg, by tonopen - 8.51 +/- 2.66 mmHg and by NCT - 13.34 +/- 3.88 mmHg. In terms of measurement results, there was a statistically significant difference between the three methods (p<0.05). Although the correlation between tonopen and CCT was insignificant (p>0.05), there was a significant correlation between GAT and CCT, as well as between NCT and CCT (p<0.05). Discussion: There was a significant difference between measurements of IOP by GAT, NCT and tonopen in normal eyes. Tonopen may not be affected by CCT in normal eyes, while a significant correlation existed between CCT and GAT or NCT in normal eyes.en_US
dc.identifier.doi10.4274/tod.40.156
dc.identifier.endpage159en_US
dc.identifier.issn1300-0659
dc.identifier.issn2147-2661
dc.identifier.issue3en_US
dc.identifier.startpage156en_US
dc.identifier.urihttps://doi.org/10.4274/tod.40.156
dc.identifier.urihttps://hdl.handle.net/11468/19709
dc.identifier.volume40en_US
dc.identifier.wosWOS:000219183300007
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isotren_US
dc.publisherTurkish Ophthalmological Socen_US
dc.relation.ispartofTurk Oftalmoloji Dergisi-Turkish Journal of Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGoldmann Applanation Tonometeren_US
dc.subjectIntraocular Pressureen_US
dc.subjectNon-Contact Tonometeren_US
dc.subjectCentral Corneal Thicknessen_US
dc.subjectTonopenen_US
dc.titleComparison of Different Methods for Measurement of Intraocular Pressure and Evaluation of Effect of Central Corneal Thickness on Measurement Resultsen_US
dc.titleComparison of Different Methods for Measurement of Intraocular Pressure and Evaluation of Effect of Central Corneal Thickness on Measurement Results
dc.typeArticleen_US