Comparison of XP-endo Finisher, self-adjusting file, and Canal Brush systems on the removal of calcium hydroxide paste from root canals

dc.contributor.authorÖzata, Merve Yeniçeri
dc.contributor.authorKaya, Sadullah
dc.contributor.authorArıkan, Nihal Firdevs Özfidan
dc.contributor.authorZengin, Ezgi İlkay
dc.contributor.authorTartuk, Gizem Akın
dc.date.accessioned2024-04-24T17:58:12Z
dc.date.available2024-04-24T17:58:12Z
dc.date.issued2023
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Endodonti Anabilim Dalıen_US
dc.description.abstractIntroduction: This study aimed to compare the effectiveness of XP-endo Finisher (XPF), self-adjusting files (SAF), and Canal Brush (CB) systems in removing calcium hydroxide (CH) from an artificial standardized groove (ASG) created in the apical root area. Methods: Fifty-five mandibular premolar teeth were prepared to size Reciproc R40 and were split longitudinally. An ASG was prepared in the apical third of the root and filled with CH. The root halves were reassembled, and the samples were divided into two control groups [positive control and negative control (n=5)] and three experimental groups [XPF, SAF, and CB, (n=15)]. The results were evaluated according to a four-grade scoring system to assess the remained CH in ASGs. The statistical difference between the groups was analyzed using the Kruskal-Wallis test. Results: There was no statistically significant difference between the experimental groups in the ability to remove CH from the apical root thirds (P>0.05). Conclusion: None of the finishing techniques could completely clean CH. The SAF, XPF, and CB systems showed comparable efficacy in removing CH from the roots. © 2023 Mashhad University of Medical Sciences\.en_US
dc.identifier.citationÖzata, M. Y., Kaya, S., Arıkan, N. F. Ö., Zengin, E. İ. ve Tartuk, G. A. (2023). Comparison of XP-endo Finisher, self-adjusting file, and Canal Brush systems on the removal of calcium hydroxide paste from root canals. Journal of Dental Materials and Techniques, 12(1), 28-34.
dc.identifier.doi10.22038/JDMT.2023.68749.1540
dc.identifier.endpage34en_US
dc.identifier.issn2322-4150
dc.identifier.issue1en_US
dc.identifier.scopus2-s2.0-85186457170
dc.identifier.scopusqualityQ4
dc.identifier.startpage28en_US
dc.identifier.urihttps://doi.org/10.22038/JDMT.2023.68749.1540
dc.identifier.urihttps://hdl.handle.net/11468/23703
dc.identifier.volume12en_US
dc.indekslendigikaynakScopus
dc.language.isoenen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofJournal of Dental Materials and Techniques
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCalcium Hydroxideen_US
dc.subjectRoot canal medicamenten_US
dc.subjectRoot canal therapyen_US
dc.titleComparison of XP-endo Finisher, self-adjusting file, and Canal Brush systems on the removal of calcium hydroxide paste from root canalsen_US
dc.titleComparison of XP-endo Finisher, self-adjusting file, and Canal Brush systems on the removal of calcium hydroxide paste from root canals
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Comparison of XP-endo Finisher, self-adjusting file, and Canal Brush systems on the removal of calcium hydroxide paste from root canals.pdf
Boyut:
227.07 KB
Biçim:
Adobe Portable Document Format
Açıklama: