Aim: The purpose of this in vitro study is to compare the cyclic fatigue resistance of Reciproc Nickel-Titanium (Ni-Ti) rotary files (VDW GmbH, Munich, Germany) while operating root canals using in three different reciprocal angles. Methodology: Forty-five Reciproc R25 root canal files were tested using artificial canals with a 60° angle of curvature, 5 mm curvature radius, and 1.5 mm diameter carved into a stainless steel block. The Ni-Ti files were checked with a stereomicroscope and then randomly separated into three groups. Group 1 consisted of reciprocal angles CCW 150°— CW 30°, Group 2 consisted of CCW 180°—CW 60°, and Group 3 consisted of CCW 210°— CW 90°. The duration of the cyclic fatigue being measured, elapsed time until a file fractured was determined with a chronometer. The lengths of the fractured pieces were measured with a digital caliper. After the cyclic fatigue test, two samples from each group were examined with a Scanning Electron Microscope (SEM) to determine the signs of cyclic fatigue. Results: One-way analysis of variance (ANOVA) was applied to the normally distributed groups (p<0,05). Since there was a significant statistical difference of file’s cyclic fatigue resistance (p=0,001) between the groups, Tukey’s honestly significant difference (HSD) post hoc pairwise comparison tests were used for determining to between groups. While there were statistically significant differences between Group 1 and Group 2 (p=0,001), and between Group 1 and Group 3 (p=0,001), there was no significant difference between Group 2 and Group 3 (p=0,376). Group 1 displayed the highest resistance to cyclic fatigue. There were no statistically significant differences between the lengths of the fractured files within the three groups according to the one-way analysis of variance (p=0,847). Conclusion: In our study, it was observed that the reciprocal angles of CCW 150°— CW 30°, which were also suggested by the file manufacturer firms, had the highest fracture resistance against cyclic fatigue.

Açıklama

Anahtar Kelimeler

Cyclic fatigue, Reciprocal movement, Kinematics, Reciproc file

Kaynak

International Dental Research

WoS Q Değeri

Scopus Q Değeri

Cilt

11

Sayı

Supplement 1

Künye

Akay, A., Adıgüzel, Ö., Akay, S. E. ve Kaya, S. (2021). Comparison of cyclic fatigue of a reciprocating file system at different angles of rotation. International Dental Research, 11(Supplement 1), 67-73.