Comparison of Vertical C/D Ratio Obtained by Assistant of Ophthalmology with Results of Optical Cohorence Tomography

dc.contributor.authorSakalar, Yildirim Bayezit
dc.contributor.authorUnlu, Kaan
dc.contributor.authorKeklikci, Selahattin Ugur
dc.contributor.authorCaca, Ihsan
dc.contributor.authorAri, Seyhmus
dc.contributor.authorBalsak, Selahattin
dc.contributor.authorAkkus, Zeki
dc.date.accessioned2024-04-24T17:44:49Z
dc.date.available2024-04-24T17:44:49Z
dc.date.issued2008
dc.departmentDicle Üniversitesien_US
dc.description.abstractPurpose: To compare vertical C/D ratio that measured with ophthalmoscopic examination of second, third and fourth year assistant of ophthalmology with vertical C/D ratio obtained by optical cohorence tomography. Materials and Methods: One hundred and ten eyes of 72 glaucoma patients which are followed in glaucoma unit were included to study. Each assistant examined vertical C/D ratio by Goldman tree mirror lens and results were recorded independently from results of the other assistants. The measurements of vertical C/D ratio were obtained by optic nerve head analyses of Stratus Optical Cohorence Tomography after pupillary dilatation and vertical C/D ratio were enlisted. All measurements of vertical C/D ratio were compared each other. Results: Thirty patients were male and 42 patients were female, mean age was 51.43 +/- 19.2. Mean vertical C/D ratio measured by second year asisstant was 0.556 +/- 0.246, mean vertical C/D ratio measured by third year assistant was 0.534 +/- 0.251, mean vertical C/D ratio measured by fourth year assistant was 0.529 +/- 0.250. Mean vertical C/D ratio obtained by optical cohorence tomography was 0.651 +/- 0.223. There was no statistically signicant differences among vertical C/D ratio measured by assistants (p>0.05). The mean vertical C/D ratio that measured by each assistant was statistically lower than obtained by optical cohorence tomography (p<0.05). Conclusions: The vertical C/D ratio that measured with ophthalmoscopic examination by assistant of ophthalmology will be different from vertical C/D ratio obtained by optic nerve head analyses of optical cohorence tomography.en_US
dc.identifier.endpage32en_US
dc.identifier.issn1300-0659
dc.identifier.issn2147-2661
dc.identifier.issue1en_US
dc.identifier.startpage28en_US
dc.identifier.urihttps://hdl.handle.net/11468/22299
dc.identifier.volume38en_US
dc.identifier.wosWOS:000218767400005
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isotren_US
dc.publisherTurkish Ophthalmological Socen_US
dc.relation.ispartofTurk Oftalmoloji Dergisi-Turkish Journal of Ophthalmology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAssistant Of Ophthalmologyen_US
dc.subjectOptical Cohorence Tomographyen_US
dc.subjectVertical C/D Ratioen_US
dc.titleComparison of Vertical C/D Ratio Obtained by Assistant of Ophthalmology with Results of Optical Cohorence Tomographyen_US
dc.titleComparison of Vertical C/D Ratio Obtained by Assistant of Ophthalmology with Results of Optical Cohorence Tomography
dc.typeArticleen_US

Dosyalar