Effect of a 50-Hz Sinusoidal Electromagnetic Field on the Integrity of Experimental Colonic Anastomoses Covered with Fibrin Glue
dc.contributor.author | Girgin, Sadullah | |
dc.contributor.author | Ozturk, Hayrettin | |
dc.contributor.author | Gedik, Ercan | |
dc.contributor.author | Akpolat, Veysi | |
dc.contributor.author | Kale, Ebru | |
dc.contributor.author | Ozturk, Hulya | |
dc.date.accessioned | 2024-04-24T17:47:57Z | |
dc.date.available | 2024-04-24T17:47:57Z | |
dc.date.issued | 2009 | |
dc.department | Dicle Üniversitesi | en_US |
dc.description.abstract | Background. Low-frequency magnetic fields have been shown to affect biological processes. In this article the effects of 50-Hz sinusoidal magnetic field (MF) stimulation and application of fibrin glue on the healing of experimental colonic anastomoses were investigated. Material and Methods. Twenty-eight rats were divided into four groups. Group 1 underwent 2-cm left colonic resection and primary anastomosis. Group 2 underwent normal resection anastomosis and the area was covered with fibrin glue. Group 3 underwent normal resection anastomosis and the rats were exposed to a 50-Hz sinusoidal MF. Group 4 underwent normal resection anastomosis, the anastomosis area was covered with fibrin glue, and the rats were exposed to a 50-Hz sinusoidal MF. Investigations included bursting pressure measurement, hydroxyproline content, and histopathological changes. Results. Tissue hydroxyproline levels and anastomotic bursting pressures of groups 2, 3, and 4 were significantly higher than in group 1. Collagen deposition and fibroblast infiltration in groups 2, 3, and 4 had higher scores than in group 1. Furthermore, these results were significantly higher in group 4 rats than in the other groups. Histopathological examination of the anastomosis revealed significantly better healing patterns for group 4 than for groups 1, 2, and 3. Conclusions. A50-Hz sinusoidal MF stimulation and application of fibrin glue provided a significant gain in anastomotic healing in the large intestine. A combination of a 50-Hz sinusoidal MF and fibrin glue has significantly favorable effects on healing of experimental colon anastomosis (Adv Clin Exp Med 2009, 18, 1, 13-18). | en_US |
dc.identifier.endpage | 18 | en_US |
dc.identifier.issn | 1899-5276 | |
dc.identifier.issn | 2451-2680 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 13 | en_US |
dc.identifier.uri | https://hdl.handle.net/11468/22822 | |
dc.identifier.volume | 18 | en_US |
dc.identifier.wos | WOS:000270038600002 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.language.iso | en | en_US |
dc.publisher | Wroclaw Medical Univ | en_US |
dc.relation.ispartof | Advances in Clinical and Experimental Medicine | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Colonic Anastomosis | en_US |
dc.subject | 50-Hz Sinusoidal Magnetic Field | en_US |
dc.subject | Fibrin Glue | en_US |
dc.title | Effect of a 50-Hz Sinusoidal Electromagnetic Field on the Integrity of Experimental Colonic Anastomoses Covered with Fibrin Glue | en_US |
dc.title | Effect of a 50-Hz Sinusoidal Electromagnetic Field on the Integrity of Experimental Colonic Anastomoses Covered with Fibrin Glue | |
dc.type | Article | en_US |