Comparison of the effects of fixed and removable functional appliances on the skeletal and dentoalveolar structures

dc.contributor.authorBilgic, Fundagul
dc.contributor.authorHamamci, Orhan
dc.contributor.authorBasaran, Guvenc
dc.date.accessioned2024-04-24T17:44:59Z
dc.date.available2024-04-24T17:44:59Z
dc.date.issued2011
dc.departmentDicle Üniversitesien_US
dc.description.abstractObjective: To compare and analyse the effects of activator and Forsus FRD EZ appliances in the treatment of skeletal Class II division I malocclusion. Methods: Lateral cephalograms and hand-wrist radiographs were collected from 24 Class II division I growing patients (14 females, 10 males). The patients were randomly divided into two equal groups and either treated with an activator appliance (Mean age 12.67 +/- 1.24 years) or with a Forsus FRD EZ appliance (Mean age 12.31 +/- 1.09 years). Pretreatment and post-treatment cephalometric radiographs were obtained, traced, superimposed and data analysed using paired t-tests and the Wilcoxon signed rank test. Results: The results demonstrated that the Forsus FRD EZ effectively corrected the Class II malocclusion, but the changes were mainly dentoalveolar. The Forsus FRD EZ appliance induced a clockwise rotation of the occlusal plane without significant alteration in the vertical facial dimension. Skeletally, maxillary growth was restricted and pogonion moved forward which improved the profile. Conclusion: The Forsus FRD EZ appliance may be an effective dentoalveolar treatment method to manage a skeletal imbalance and improve the profile in growing patients. (Aust Orthod J 2011; 110-116)en_US
dc.identifier.endpage116en_US
dc.identifier.issn0587-3908
dc.identifier.issue2en_US
dc.identifier.startpage110en_US
dc.identifier.urihttps://hdl.handle.net/11468/22372
dc.identifier.volume27en_US
dc.identifier.wosWOS:000297831400004
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.language.isoenen_US
dc.publisherAustralian Soc Orthodontists Incen_US
dc.relation.ispartofAustralian Orthodontic Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject[No Keyword]en_US
dc.titleComparison of the effects of fixed and removable functional appliances on the skeletal and dentoalveolar structuresen_US
dc.titleComparison of the effects of fixed and removable functional appliances on the skeletal and dentoalveolar structures
dc.typeArticleen_US

Dosyalar