Farklı açılardaki farklı abutment materyallerinin kullanıldığı maksiller anterior tek diş implantlarda oluşan streslerin analitik olarak incelenmesi: Bir sonlu elemanlar analizi

dc.authorid0000-0001-9267-4173en_US
dc.authorid0000-0003-0907-7349en_US
dc.authorid0000-0002-2598-227Xen_US
dc.contributor.authorKızmaz, Said Mirza
dc.contributor.authorBeydemir, Köksal
dc.contributor.authorAgüloğlu, Süleyman
dc.date.accessioned2023-06-06T08:04:01Z
dc.date.available2023-06-06T08:04:01Z
dc.date.issued2022en_US
dc.departmentDicle Üniversitesi, Diş Hekimliği Fakültesi, Protetik Diş Tedavisi Bölümüen_US
dc.description.abstractAmaç: Çalışmanın amacı, maksiller anterior bölgelerde açılı titanyum ve zirkonya abutment kullanıldığı durumlarda, okluzal streslerin implant, abutment, restorasyon ve çevre dokularda oluşturduğu streslerin analiz edilmesidir. Bu sayede başarılı bir implant uygulaması için hangi materyallerin hangi açılarda daha başarılı olduğunun tespit edilmesi amaçlanmıştır. Gereç ve Yöntemler: Çalışmada stres analiz yöntemlerinden biri olan ve teknolojinin gelişmesiyle birçok alanda sıklıkla kullanılan sonlu elemanlar analizi yöntemi kullanılmıştır. Maksillar anterior tek diş implant destekli restorasyon modelleri titanyum ve zirkonya abutment materyallerinin implant ile 0° ve 25° açı yaptığı modeller bilgisayar ortamında hazırlanmıştır. Üç boyutlu olarak bilgisayar ortamında hazırlanan bu modellere çiğneme ve kesme kuvvetleri uygulanmış ve uygulanan bu kuvvetler sonucunda implantta, abutmentte, restorasyonda, implant vidasında, çevre kemik dokuda oluşan stresler incelenerek kıyaslanmıştır. Bulgular: Maksiller anterior tek diş eksikliklerinde zirkonya abutmentler 0° ve 25° açılı kullanımda kesme ve çiğneme kuvvetlerine karşı titanyum abutmentlere benzer stres birikimleri göstermiştir. Hem zirkonya hem de titanyum abutmentlerde 25° açılandırıldıklarında açısız kullanımına göre %30 oranında stres artışı görülmüştür. Abutment vidasında ise açılı kullanımda stresin 3 kat arttığı görülmüştür. Sonuç: Estetik beklentileri karşılamak için maksiller anterior bölgede kullanılan zirkonya abutmentler çiğneme ve kesme kuvvetleri karşısında oluşan stresler açısından titanyum abutmentlere benzer stresler oluşturduğundan hem açılı hem de düz kullanımının titanyum abutmentlerden farklı sonuçlar doğurmayacağı anlaşılmıştır. Abutment vidalarında 25° açılı kullanımda 3 kat fazla stres oluştuğu tespit edildiğinden tasarım ve materyal kalitesinin dikkate alınması gerektiği görülmüştür. Konu ile ilgili in vivo çalışmaların yapılması gerektiği düşünülmektedir.en_US
dc.description.abstractObjective: Aim of the study is analyzing the stresses caused by occlusal stresses on the implant, abutment, restoration and surrounding tissues in cases where angled titanium and zirconia abutments are used in the maxillary anterior regions. In this way, it is aimed to determine which materials and which angles should be used for a successful implant application. Material and Methods: Finite element analysis method, which is frequently used in many areas with the development of technology, was used in the study. Maxillary anterior single implant supported restoration models were prepared in computer environment where titanium and zirconia abutment materials prepared 0° and 25° angles with the implant. Chewing and shearing forces were applied to these models, which were prepared in three dimensions in the computer environment, and as a result of these applied forces, the stresses on the implant, abutment, restoration, implant screw, and surrounding bone tissue were examined and compared. Results: In maxillary anterior single tooth deficiencies zirconia abutments showed similar stress cumulations to titanium abutments when they are used with 0° and 25° angle. On both zirconia and titanium abutments, when they are tilted 25°, an increase in stress of 30% was observed compared to the non-tilted use. It is observed that the stress increased three times more on abutment screw with the use of angle. Conclusion: Since zirconia abutments used in the maxillary anterior region to meet aesthetic expectations create stresses similar to titanium abutments in terms of stresses against chewing and shear forces, it has been understood that both angled and straight use will not produce different results than titanium abutments. Abutment screws have been found to have 3 times more stress at 25° angles, so design and material quality have to be taken into consideration. It is thought that supportive in vivo studies should be performed.en_US
dc.identifier.citationKızmaz, S. M., Beydemir, K. ve Agüloğlu, S. (2022). Farklı açılardaki farklı abutment materyallerinin kullanıldığı maksiller anterior tek diş implantlarda oluşan streslerin analitik olarak incelenmesi: Bir sonlu elemanlar analizi. Türkiye Klinikleri Diş Hekimliği Bilimleri Dergisi, 28(4), 898-904.en_US
dc.identifier.doi10.5336/dentalsci.2022-89759
dc.identifier.endpage904en_US
dc.identifier.issn1300-7734
dc.identifier.issn2146-8966
dc.identifier.issue4en_US
dc.identifier.startpage898en_US
dc.identifier.trdizinid1171121
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1171121
dc.identifier.urihttps://hdl.handle.net/11468/11967
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1171121
dc.identifier.volume28en_US
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorBeydemir, Köksal
dc.language.isotren_US
dc.publisherTürkiye Klinikleri Yayınevien_US
dc.relation.ispartofTürkiye Klinikleri Diş Hekimliği Bilimleri Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDental implanten_US
dc.subjectZirkonya abutmenten_US
dc.subjectSonlu elemanlar analizien_US
dc.subjectDental implanten_US
dc.subjectAbutmenten_US
dc.subjectZirconia abutmenten_US
dc.subjectFinite element analysisen_US
dc.titleFarklı açılardaki farklı abutment materyallerinin kullanıldığı maksiller anterior tek diş implantlarda oluşan streslerin analitik olarak incelenmesi: Bir sonlu elemanlar analizien_US
dc.titleFarklı açılardaki farklı abutment materyallerinin kullanıldığı maksiller anterior tek diş implantlarda oluşan streslerin analitik olarak incelenmesi: Bir sonlu elemanlar analizi
dc.title.alternativeAnalytically tnvestigation of stress created in maxillary anterior single dental implants using different abutment materials at different angles: A finite element analysisen_US
dc.title.alternativeAnalytically tnvestigation of stress created in maxillary anterior single dental implants using different abutment materials at different angles: A finite element analysis
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Farklı Açılardaki Farklı Abutment Materyallerinin Kullanıldığı Maksiller Anterior.pdf
Boyut:
698.22 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: