Analysis of the effect of air gaps on the electric field in the insulation material of high voltage transmission cables

dc.authorid0000-0001-8461-8702en_US
dc.contributor.authorÖzüpak, Yıldırım
dc.date.accessioned2023-08-03T12:09:15Z
dc.date.available2023-08-03T12:09:15Z
dc.date.issued2022en_US
dc.departmentDicle Üniversitesi, Silvan Meslek Yüksek Okulu, Elektrik ve Enerji Bölümüen_US
dc.description.abstractHigh voltage (HV) cables are widely used in the transmission and distribution of electrical energy. The design and manufacture of these cables with great precision are of great importance for power systems. Mistakes made during the manufacturing phase and defects that may occur in the structure of the cable material can cause premature aging and continuous malfunctions in the cables. Factors such as air gaps, foreign substances, and moisture in the insulating material may cause punctures and insulation problems in high voltage cables. In this study, the effects of air gaps left as manufacturing defects on the electric field distribution in the insulation of high voltage cables used in power systems were investigated. The effects of 154 kV high voltage cable, the air gap in different coordinates, and diameters in the insulating layer on the electric field distribution in the cable have been investigated. For this analysis, the Finite Element Method (FEM) and ANSYS@Workbench program which realizes a solution based on this method were used. It has been found that the diameter and location of the air gap significantly affect the electric field distribution of the high voltage cable.en_US
dc.description.abstractElektrik enerjisinin iletimi ve dağıtımında yüksek gerilim (YG) kabloları yaygın olarak kullanılmaktadır. Bu kabloların tasarım ve imalatlarının büyük bir hassasiyetle gerçekleştirilmesi güç sistemleri için büyük önem teşkil etmektedir. İmalat aşamasında yapılan hatalar ile kablo malzemesinin yapısında oluşabilecek bozukluklar, kablolarda erken yaşlanma ve sürekli arızalara neden olabilmektedir. Yalıtkan malzeme içerisinde hava boşlukları, yabancı maddeler ve nem gibi etmenler yüksek gerilim kablolarında delinmeye ve yalıtım sorunlarının meydana gelmesine neden olabilmektedir. Bu çalışmada, güç sistemlerinde kullanılan yüksek gerilim kablolarının yalıtımında, imalat hatası olarak bırakılan hava boşluklarının elektrik alan dağılımı üzerindeki etkileri incelenmiştir. 154 kV’luk yüksek gerilim kablosunun, yalıtkan tabakasında farklı koordinatlarda ve çaplardaki hava boşluğunun kablodaki elektrik alan dağılımı üzerindeki etkileri incelenmiştir. Bu analiz için Sonlu Elemanlar Yöntemi ve bu yönteme dayanarak çözüm gerçekleştiren ANSYS@Workbench programı kullanılmıştır. Hava boşluğu çapının ve konumunun yüksek gerilim kablosunun elektrik alan dağılımına önemli ölçüde etki ettiği görülmüştür.en_US
dc.identifier.citationÖzüpak, Y. (2022). Analysis of the effect of air gaps on the electric field in the insulation material of high voltage transmission cables. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 15(1), 69-79.en_US
dc.identifier.doi10.18185/erzifbed.952750
dc.identifier.endpage79en_US
dc.identifier.issn1307-9085
dc.identifier.issn2149-4584
dc.identifier.issue1en_US
dc.identifier.startpage69en_US
dc.identifier.trdizinid1067516
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1067516
dc.identifier.urihttps://hdl.handle.net/11468/12416
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1067516
dc.identifier.volume15en_US
dc.indekslendigikaynakTR-Dizin
dc.institutionauthorÖzüpak, Yıldırım
dc.language.isoenen_US
dc.publisherErzincan Binali Yıldırım Üniversitesi Fen Bilimleri Enstitüsüen_US
dc.relation.ispartofErzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectElectromagnetic fielden_US
dc.subjectHV cableen_US
dc.subjectFinite Element Method (FEM)en_US
dc.subjectANSYSen_US
dc.subjectElektromanyetik akıen_US
dc.subjectYG kablolarıen_US
dc.subjectSonlu Elemanlar Yöntemi (SEY)en_US
dc.titleAnalysis of the effect of air gaps on the electric field in the insulation material of high voltage transmission cablesen_US
dc.titleAnalysis of the effect of air gaps on the electric field in the insulation material of high voltage transmission cables
dc.title.alternativeYüksek gerilim iletim kablolarının yalıtım malzemesindeki hava boşluklarının elektrik alana etkisinin analizien_US
dc.title.alternativeYüksek gerilim iletim kablolarının yalıtım malzemesindeki hava boşluklarının elektrik alana etkisinin analizi
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Analysis of the Effect of Air Gaps on the Electric Field in the Insulation Material of High Voltage Transmission Cables.pdf
Boyut:
556.27 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: