Evaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopy

dc.contributor.authorEskibağlar, Mehmet
dc.contributor.authorÖzata, Merve Yeniçeri
dc.contributor.authorOcak, Mevlüt Sinan
dc.contributor.authorÖztekin, Faruk
dc.date.accessioned2025-02-22T14:18:01Z
dc.date.available2025-02-22T14:18:01Z
dc.date.issued2023
dc.departmentDicle Üniversitesien_US
dc.description.abstractPurpose: The aim of this study was to evaluate the matching properties of the gutta-percha (GP) cones and different file systems with variable tapers. Methods: Fifteen files and GP cones TruNatomy Prime (TRN-P), WaveOne Gold Primary (WOG-P), and Reciproc Blue (Rec-B R25) systems were examined under a scanning electron microscope. Diameter measurements of files and GP cones were made from D1 to D16 using AutoCAD software. Data were analyzed with independent samples t-tests. Statistical significance was determined as p< 0.05. Results: The diameters of the file and GP cones were within the acceptable tolerance range. The file diameter was larger than the GP diameter at all points of incompatibility in the TRN-P system (p< 0.05). In the WOG-P group, the file diameter was wider up to the D10 level, while the GP cone diameter was wider at the D11 point and beyond p<0.05. In the Rec-B group, the file diameter was wider up to the D6 level, while the GP cone diameter was wider at the D7 point and beyond p<0.05. Conclusion: Three file systems are largely incompatible with the GP cones. In the TRN file system, unlike the other two groups, the GP cone had a narrower diameter than the file at each point.en_US
dc.identifier.doi10.14744/TEJ.2023.1948
dc.identifier.endpage19en_US
dc.identifier.issn2459-1726
dc.identifier.issue1en_US
dc.identifier.startpage15en_US
dc.identifier.trdizinid1239686en_US
dc.identifier.urihttps://doi.org/10.14744/TEJ.2023.1948
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1239686
dc.identifier.urihttps://hdl.handle.net/11468/30210
dc.identifier.volume8en_US
dc.indekslendigikaynakTR-Dizin
dc.language.isoenen_US
dc.relation.ispartofTurkish Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.snmzKA_TR_20250222
dc.subjectDiameteren_US
dc.subjectstandardizationen_US
dc.subjectTruNatomyen_US
dc.subjectreciproc blueen_US
dc.subjectrotary file systemsen_US
dc.subjectWaveOne Golden_US
dc.titleEvaluation of compatibility of file and gutta-percha cones in three different endodontic systems using scanning electron microscopyen_US
dc.typeArticleen_US

Dosyalar