High voltage upper extremity electrical burns repair with groin flap

dc.contributor.authorSelçuk C.T.
dc.contributor.authorBozkurt B.
dc.contributor.authorDurgun M.
dc.contributor.authorÖzalp B.
dc.contributor.authorKapi E.
dc.contributor.authorAkkoç M.F.
dc.date.accessioned2024-04-24T18:43:42Z
dc.date.available2024-04-24T18:43:42Z
dc.date.issued2012
dc.departmentDicle Üniversitesien_US
dc.description.abstractUpper extremities are significantly affected by high-voltage electrical injuries. In this study, the repair of the upper extremity tissue defects due to high-voltage electrical injuries using groin flaps is discussed. Methods: Ten patients who developed upper extremity tissue defects following high-voltage (>1000 V) electrical injuries between April 2009 and October 2011 were enrolled in our study. All the patients underwent reconstructions with pedicled groin flaps. All the patients were male. The areas on which the reconstructions were performed were hand and wrist areas where structures like the bones, tendons and nerves are accessible. The separation of the pedicles was performed on days 20-27 (average period: 23 days) after the pedicle ligation examination revealed no problems. Result: Adequate soft tissue coverage was obtained in all patients following the reconstruction. All the flaps healed without problem. No donor area morbidity was observed. No articular rigidity related to the operation was observed in any of the patients. Conclusion: We are of the opinion that in soft tissue defects that form in the upper extremities subsequent to high-voltage electrical injuries, when local flaps or free tissue transplants are risky or inapplicable, reconstruction with pedicled groin flaps constitutes an ideal treatment alternative.en_US
dc.identifier.endpage16en_US
dc.identifier.issn1300-6878
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-84879217030
dc.identifier.scopusqualityN/A
dc.identifier.startpage11en_US
dc.identifier.urihttps://hdl.handle.net/11468/24305
dc.identifier.volume20en_US
dc.indekslendigikaynakScopus
dc.language.isotren_US
dc.relation.ispartofTurk Plastik, Rekonstruktif ve Estetik Cerrahi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectrical Burnen_US
dc.subjectGroin Flapen_US
dc.subjectHanden_US
dc.subjectWristen_US
dc.titleHigh voltage upper extremity electrical burns repair with groin flapen_US
dc.titleHigh voltage upper extremity electrical burns repair with groin flap
dc.title.alternativeYüksek voltajli üst ekstremite elektrik yaniklarinda kasik flebi ile onarimen_US
dc.title.alternativeYüksek voltajli üst ekstremite elektrik yaniklarinda kasik flebi ile onarim