Buhar sıkıştırmalı bir soğutma sisteminde R22 yerine N20 ve R444B soğutucu akışkanlarını kullanmanın termodinamik performansa etkisi
Devecioğlu, Atilla Gencer; Oruç, Vedat (2016)Bu çalışmada buhar sıkıştırmalı bir soğutma sisteminde R22 soğutucu akışkanı yerine N20 ve L20 (R444B) soğutucu akışkanının kullanılmasıyla enerji ve ekserji parametreleri teorik olarak incelenmiştir. Aynı çalışma şartları ... -
A COMPARATIVE ENERGETIC ANALYSIS FOR SOME LOW-GWP REFRIGERANTS AS R134a REPLACEMENTS IN VARIOUS VAPOR COMPRESSION REFRIGERATION SYSTEMS
Oruç, Vedat; Devecioğlu, Atilla G (2018)In this study, the energy parameters (i.e., cooling capacity and COP) were theoretically investigated for three different vapour compression refrigeration system (basic cycle, basic cycle with liquid-to-suction heat exchanger ... -
Dairesel bir silindir ardındaki pasif akış kontrolünün hesaplamalı akışkanlar dinamiğiyle incelenmesi
Biçer, Uğur (Dicle Üniversitesi, Fen Bilimleri Enstitüsü, 2023)Küt bir cisme etki eden dış akışlar, akış alanı içerisinde cismin arkasında girdaplara yol açarak düzensiz ve zamana göre değişen akış davranışları gösterirler. Dairesel silindir gibi küt cisimler arkasında oluşan akış ... -
Drop-in assessment of plug-in R404A refrigeration equipment using low-global warming potential mixtures
Devecioğlu, Atilla G.; Oruç, Vedat (Oxford University Press, 2022)This study analyzes the performance of plug-in refrigeration equipment, which has the condenser on the system and delivers heat to the indoor medium, using mixtures with low-global warming potential (GWP). The theoretical ... -
Energetic performance analysis of R466A as an alternative to R410A in VRF systems
Devecioğlu, Atilla Gencer; Oruç, Vedat (Elsevier B.V., 2020)In this study, utilization of R466A with low-GWP is investigated in variable refrigerant flow (VRF) systems. R410A is widely used in VRF systems. Only non-flammable refrigerants are allowed for these systems since they ... -
Experimental and numerical analysis of a parabolic trough solar collector for water heating application
Özcan, Abdulkadir; Devecioğlu, Atilla Gencer; Oruç, Vedat (Taylor & Francis, 2022)The aim of this study is to obtain hot water utilizing a parabolic trough solar collector. The copper tube and aluminum absorber tube were placed separately through the focus point of the parabolic reflector. The steady ... -
Experimental assessment of the retrofit of an internal heat exchanger in refrigeration systems: The effect on energy performance and system operation
Oruç, Vedat; Devecioğlu, Atilla G. (Pergamon-Elsevier Science LTD, 2020)The aim of this experimental study is to retrofit a refrigeration system with an internal heat exchanger (IHX) and to assess its effect on the energy performance of the system. The separate IHX cases in the investigation ... -
Experimental comparison of R404A and R452A in refrigeration systems
Devecioğlu, Atilla G.; Oruç, Vedat (Taylor & Francis, 2021)In this study, R404A and R452A refrigerants used in refrigeration systems were compared experimentally. The energy performance of the system was investigated for widely used evaporation temperatures (−5, 0, +5 °C) and ... -
Experimental investigation of a solar air heater with copper wool on the absorber plate
Biçer, Ayşe; Devecioğlu, Atilla G.; Oruç, Vedat; Tuncer, Zafer (Taylor & Francis, 2020)The thermal performance of a novel solar air heater was experimentally studied in this paper. For this aim, a new solar air collector was designed using copper wool on its absorber plate to be a selective surface. Hence, ... -
Experimental investigation of thermal performance of a new solar air collector with porous surface
Devecioğlu, Atilla G.; Oruç, Vedat (Elsevier Ltd, 2017)In this study, thermal performance of a new solar air collector with porous absorber plate was investigated. The porous surface was accomplished by laying out the copper meshing on the absorbing plate. Hence, it was aimed ... -
Experimental investigation on the low-GWP HFC/HFO blends R454A and R454C in a R404A refrigeration system
Oruç, Vedat; Devecioğlu, Atilla G. (Elsevier SCI LTD., 2021)This study experimentally compares the high-GWP R404A with two low-GWP HFC/HFO blends, R454A (35% R32 + 65% R1234yf) and R454C (21.5% R32 + 78.5% R1234yf). Three evaporation temperatures ( -5, 0 and + 5 degrees C) and three ... -
Flow around a cylinder surrounded by a permeable cylinder in shallow water
Özkan, Göktürk M.; Oruç, Vedat; Akıllı, Hüseyin; Şahin, Beşir (Springer, 2012)The change in flow characteristics downstream of a circular cylinder (inner cylinder) surrounded by an outer permeable cylinder was investigated in shallow water using particle image velocimetry technique. The diameter of ... -
HCFC-22 YERİNE KULLANILAN BAZI HFC'LERİN ÇEVRESEL ETKİLERİNİN DENEYSEL OLARAK KARŞILAŞTIRILMASI
Devecioğlu, Atilla G; Oruç, Vedat (2016)Bu çalışmada, HCFC-22 gazı yerine ozon tabakasına zarar vermeyen R417A ve R424A soğutucu akışkanlarının TEWI değerleri hesaplanıp, mukayese edilmiştir. Bir split klima cihazı için, ortalama 38?C çevre sıcaklığında, üç ... -
İklimlendirme sistemlerinde R22 yerine R442A kullanılmasının enerji parametrelerine etkisinin incelenmesi
Devecioğlu, Atilla G.; Oruç, Vedat; Berk, Uğur; Ender, Sertaç (Dicle Üniversitesi Mühendislik Fakültesi, 2016)Bu çalışmada buhar sıkıştırmalı iklimlendirme cihazında R22 soğutucu akışkanı yerine R442A kullanılması deneysel olarak incelenmiştir. Sistemde sadece kompresör yağı değiştirilmiştir. R22 ile çalışırken mineral yağ ... -
On the satisfaction of EU F-Gas regulation using R455A as an alternative to R404A in refrigeration systems
Devecioğlu, Atilla G.; Oruç, Vedat (Elsevier, 2022)The aim of this study is to investigate the possibilities for satisfying F-Gas regulation of European Union (EU) using R455A with low-global warming potential (GWP) in refrigeration systems. Hence an experimental work was ... -
Passive control of flow structures around a circular cylinder by using screen
Oruç, Vedat (Elsevier, 2012)he results of PIV measurements are presented in this paper for the water flow downstream of a circular cylinder surrounded with a screen (meshed outer control element) which had a streamlined shape. The diameter of cylinder, ... -
PIV measurements on the passive control of flow past a circular cylinder
Oruç, Vedat; Akıllı, Hüseyin; Şahin, Beşir (Elsevier, 2016)The passive control of water flow downstream of a circular cylinder with 50 mm diameter is experimentally investigated in this study using particle image velocimetry (PIV) technique. The experiments were carried out for ... -
R22 ile çalışan bir iklimlendirme sisteminde R417A ile R422D alternatif soğutucu akışkanlarının kullanılmasının termodinamik analizi
Vural, İbrahim (Dicle Üniversitesi, Fen Bilimleri Enstitüsü, 2019)Bu çalışmanın amacı, HCFC-22 (Hidrokloroflorokarbon) soğutucu akışkanıyla çalışan bir klima cihazının, ozon dostu HFC-417A ve HFC-422D soğutucu akışkanlarıyla yapılan ölçümlerle, soğutma kapasitesi ve performans katsayısı ... -
R422A ve R424A soğutucu akışkanlarıyla çalışan bir soğutma sisteminin deneysel incelenmesi
Berk, Uğur (Dicle Üniversitesi, Fen Bilimleri Enstitüsü, 2019)Araştırmacılar, 1974 yılında HFC'lerin emisyon değerlerinin stratosferdeki ozon tabakasını delerek Dünya atmosferine zarar verebileceği seviyede olduğunu öngörmüşlerdir. 1985 yılına gelindiğinde, Antarktika üzerinde bulunan ...