Yazar "Tekin, Samet" seçeneğine göre listele
Listeleniyor 1 - 15 / 15
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Areas for use of PEEK material in dentistry(Uluslararası Diş Araştırmaları Birliği, 2018) Tekin, Samet; Cangül, Suzan; Adıgüzel, Özkan; Değer, YalçınPolyetheretherketone (PEEK) material is a polycyclic, aromatic,thermoplastic polymer that is semi-crystalline and has a linearstructure. PEEK has good mechanical and electrical properties such asresistance to high temperature and resistance to hydrolysis. Inaddition, because of the property of high biocompatibility, use of PEEKhas increased in orthopedic and trauma cases. The most characteristicproperty of PEEK material is that it has a low elasticity modulus, closeto that of bone. It has been suggested that stress-based problemscould be reduced with this material due to the low elasticity modulus.In the light of this information, PEEK material could be considered asan alternative to conventional materials in the field of dentistry.Öğe Biomechanical and biochemical evaluation of the effect of systemic application of omeprazole on the osseointegration of titanium implants(Springer, 2021) Tekin, Samet; Dündar, Serkan; Demirci, Fatih; Bozoğlan, Alihan; Yıldırım, Tuba Talo; Güneş, Nedim; Acıkan, Izzet; Özcan, Erhan CahitBackground This study aimed to investigate the effects of systemic omeprazole treatment on the osseointegration of titanium implants. Material and methods After surgical insertion of titanium implants into the metaphyseal part of rats' both right and left tibial bones, the animals were randomly divided into three equal groups: control (n = 8), omeprazole dosage-1 (n = 8) (OME-1), and omeprazole dosage-2 (n = 8) (OME-2) and totally 48 implants were surgically integrated. The rats in the control group received no treatment during the four-week postoperative experimental period. In the OME-1 and OME-2 groups, the rats received omeprazole in doses of 5 and 10 mg/kg, respectively, every 3 days for 4 weeks. After the experimental period, the rats were euthanized. One rat died in each group and the study was completed with seven rats in each group. Blood serum was collected for biochemical analysis, and the implants and surrounding bone tissue were used for biomechanical reverse-torque analysis. In the biomechanical analysis, implants that were not properly placed and were not osseointegrated were excluded from the evaluation. Results One-way analysis of variance and Tukey's honestly significant difference test and Student's t test were used for statistical analysis. The reverse-torque test (control (n = 9), OME-1 (N = 7), and OME-2 (n = 7)) analysis of biochemical parameters (alkaline phosphatase, calcium, phosphorus, aspartate aminotransferase, alanine amino transferase, urea, and creatinine) revealed no significant differences between the groups (control (n = 7), OME-1 (N = 7), and OME-2 (n = 7)) (P > 0.05). Conclusions Omeprazole had no biomechanical or biochemical effects on the osseointegration process of titanium implants.Öğe Biomechanical Evaluation of Implant Osseointegration After Guided Bone Regeneration With Different Bone Grafts(Lippincott Williams & Wilkins, 2021) Gunes, Nedim; Gul, Mehmet; Dundar, Serkan; Tekin, Samet; Bozoglan, Alihan; Ozcan, Erhan Cahit; Karasu, NecmettinThe aim of this study was to compare the biomechanical osseointegration of titanium implants after guided bone regeneration (GBR) with a hydroxyapatite graft, deproteinized bovine bone graft, human-derived allograft, and calcium sulfate bone graft. Thirty-two female Sprague Dawley rats were divided into four groups, each containing eight (n = 8) rats: hydroxyapatide (HA), deproteinized bovine bone graft (DPBB), allograft (ALG), and calcium sulfate. Bone defects were created in the tibia of the rats, which were grafted with HA, DPBB, ALG, or CP bone grafts for the purpose of GBR. Ninety days after surgery, machine-surfaced titanium implants were inserted into the area where GBR had been undertaken. After 90 days of the surgical insertion of the implants, the rats were sacrificed, the implants with surrounding bone tissue were removed, and biomechanical osseointegration (N/cm) analysis was performed. No statistically significant differences were found among the groups in osseointegration (N/cm) three months after the GBR procedures (P > 0.05). According to the biomechanical results, none of the grafts used in this study was distinctly superior to any of the others.Öğe Comparative stress analysis of custom-made PEEK dental post-cores versus conventional post-cores in incisor restorations: A finite element study(International Scientific Information, Inc., 2023) Yıldız, Şemsettin; Tekin, Samet; Kızılkaya, Ayşe Rençber; Akgün, Semih Ercan; Değer, YalçınBackground: We conducted a finite element analysis to evaluate stress levels in incisor teeth restored with custom polyetheretherketone (PEEK) dental post-cores compared to conventional post-cores. Material/Methods: Using micro-computed tomography (μCT) imaging data, a 3D model of a maxillary incisor was created. For each material type, 3D mesh models were developed via specialized software. Two post diameters, 2.5 mm and 3.5 mm, were considered. Five different post materials were examined: Unfilled polyetheretherketone (Group UP); Glass fiber-reinforced polyetheretherketone (Group GP); Carbon fiber-reinforced polyetheretherketone (Group CP); Metal (Group M); and Zirconia ceramic (Group Z). Each model underwent finite element analysis, after which the von Mises equivalent stress values were determined. Results: For models involving both wide and narrow diameter posts across the crown, crown cement, post cement, and dentin, PEEK posts (Group UP, GP, and CP) exhibited higher von Mises stress values than Groups Z and M. However, the reverse trend was noticed in the post model itself. In the post cement model, stress values appeared similar only for the narrow-diameter post groups. Notably, results for Groups Z and M were largely consistent with each other. Conclusions: PEEK posts, which have a lower modulus of elasticity, demonstrated different stress values when contrasted with zirconia and metal posts. As the post diameter expanded, the residual dentin decreased, influencing the stress values among various materials. Further in vitro and clinical examinations are essential to comprehensively understand PEEK posts.Öğe Comparison of Cytotoxicity of Four Different Adhesive Materials Before and After Polymerisation(Quintessence Publishing Co Inc, 2020) Cangul, Suzan; Adiguzel, Ozkan; Tekin, SametIntroduction: The aim of this study was to make a quantitative comparison of the cytotoxic potentials of four different polymerised and unpolymerised self-etching adhesives which were newly used clinically. Materials and Methods: Cytotoxic effects of both polymerised and unpolymerised forms of all test adhesives were evaluated against L929 cell line using the MTT test. The activity for unpolymerised adhesives was assessed in different doses and incubation times manner. On the other hand, cytotoxicity of the polymerised adhesives prepared at different extraction times were evaluated as dependent on incubation times. Two-Way Variance Analysis and Bonferroni post-test was used for statistical evaluation. Results: There were statistically significant differences between the groups (p < 0.05). In general, it was shown that unpolymerised and polymerised forms of each of the test compounds exhibited a time-dependent cytotoxic effect. However, the effect on polymerised forms was found to be independent of the duration of the extraction, while the effect on the unpolymerised forms increased dose-dependently. It was also determined that the most cytotoxic material in the unpolymerised form was Dentsply and in the polymerised form was Tokuyama. Conclusions: Dentsply should be preferred over Tokuyama to be able to provide clinically long-lasting restorations.Öğe A COMPARISON OF THE WATER ABSORPTION AND WATER SOLUBILITY VALUES OF FOUR DIFFERENT COMPOSITE RESIN MATERIALS(2018) Adıgüzel, Özkan; Öztekin, Faruk; Satıcı, Ömer; Cangül, Suzan; Tekin, SametObjectives: The aim of this study was to compare thewater absorption and water solubility of four differentcomposte resin materials.Materials and Methods: A total of 40 cylindrical discswere prepared and polymerised with light, as 10 fromeach group, each sample 2 mm in depth and 8 mm indiameter. The samples were kept for 24 hrs in adessicator until a stable weight was reached. Then, theweight of each sample was measured on highly sensitivescales. To calculate the water absorption and solubility,measurements were made again with the sensitive scalesat the end of 1, 7 and 30 days. The data obtained wereevaluated with One-Way ANOVA variance analysis andthe Friedman test.Results: As a result of the statistical analyses, significantdifferences were determined between the compositeresins in respect of water absorption on days 7 and 30 andin respect of solubility on day 30 only (p<0.05).Conclusion: When the water absorption and watersolubility of composite resins at the end of 30 days wereevaluated statistically, it was observed that Ceram X Onematerial showed the lowest values. This is related to thestructure of the restorative material.It can be concluded that the negative mechanical,physical and biological effects created by the waterabsorption and water solubility factors of restorativematerials are important issues that should be taken intoconsideration.Öğe Does the Use of Ozone as a Cavity Disinfectant Affect the Bonding Strength of Antibacterial Bonding Agents?(Taylor & Francis Inc, 2020) Cangul, Suzan; Erpacal, Begum; Adiguzel, Ozkan; Sagmak, Savas; Unal, Server; Tekin, SametThe aim of this study was to evaluate the use of ozone as cavity disinfectant on the bonding strength to dentin of different antibacterial bonding agents. The study was conducted on 60 cavity-free 3rd molar teeth. The prepared samples were separated into 3 groups. These groups were each sub-divided into 2 groups of 10 as a group with ozone applied and a control group. In Group 1a, ozone was applied as cavity disinfectant for 6 secs to all the exposed dentin surfaces then restoration was applied. In Group 1b as the control group, the restoration stages were applied without any cavity disinfection. Gluma 2 Bond, our first antibacterial adhesive material, was applied to all dentin surfaces and polymerized. The second and third groups were divided into two groups. Clearfil SE Protect Primer and Clearfil SE Protect Bond were applied in the group 2. Peak Universal was used in Group 3. After the application of the adhesive materials and then Estelite posterior quick composite was applied and polymerized. The bonding strengths of all the samples were measured in an Instron test device. The data were statistically analyzed using the Mann Whitney U-test and the Kruskal Wallis test. The highest bonding strength was determined in Gluma 2 Bond (7,79), and the lowest bonding strength was in Peek Universal (3,43). It was concluded that ozone adhesive systems can be safely currently used as they have been shown to increase bonding strength and can eliminate bacteria.Öğe Effects of Systemic Propranolol Application on the New Bone Formation in Periimplant Guided Bone Regeneration(Uab Stilus Optimus, 2021) Gunes, Nedim; Gul, Mehmet; Dundar, Serkan; Artas, Gokhan; Kobat, Mehmet Ali; Tekin, Samet; Bozoglan, AlihanObjectives: The aim of this experimental animal study was to evaluate the effects of systemic propranolol on new bone formation in peri-implant bone defects. Material and Methods: Implant slots were created 4 mm long and 2.5 mm wide. After the titanium implants were placed in the sockets, 2 mm defects were created in the neck of the implants. Bone grafts were placed in these defects. Then the rats were randomly divided into three equal groups: control (n = 8), propranolol dose-1 (PRP-1) (n = 8), and propranolol dose-2 (PRP-2) (n = 8) groups. In the control group, the rats received no further treatment during the eight-week experimental period after the surgery. The rats in the PRP-1 and PRP-2 groups were given 5 mg/kg and 10 mg/kg propranolol, respectively, every three days for the eight-week experimental period after the surgery. At the end of the experimental period, the rats were euthanized. Blood serum was collected for biochemical analysis, and the implants and surrounding bone tissues were used for the histological analysis. Results: There were no significant differences in the histological analysis results and the biochemical parameters (alkaline phosphatase, calcium, creatinine and phosphorus) of the groups (P > 0.05). Also, in the test groups, there was numerically but not statistically more new bone formation detected compared with the controls. Conclusions: Within the limitations of this study, propranolol did not affect the new bone formation in peri-implant defects.Öğe Ektodermal displazili olgularda klinik ve radyolojik bulguların incelenmesi(Fırat Üniversitesi Tıp Fakültesi, 2019) Doğan, Mehmet Sinan; Ataş, Osman; Yavuz, İzzet; Tekin, SametAmaç: Ektodermal displazi; deri, tırnak, saç, ter bezleri ve diş gibi ektoderm kaynaklı dokuları etkileyen ve nadir olarak rastlanan kalıtsal bir hastalıktır. Bu çalışmada fakülte hastanemize başvuran ektodermal displazili olgulardaki; sistemik ve dental bulguların klinik ve radyolojik olarak değerlendirilmesi amaçlanmıştır.Gereç ve Yöntem: Çalışmamızda 2006-2017 yılları arasında Dicle Üniversitesi Diş Hekimliği Fakültesi hastanesine diş eksikliği şikayetiyle başvuran, 49 ektodermal displazi olgusu retrospektif olarak değerlendirildi. Klinik değerlendirmede saç, tırnak, deri, diş, burun, ter bezleri ve benzeri malformasyonlar incelendi. Radyolojik muayenede; geleneksel radyografi ve konik ışınlı bilgisayarlı tomografi kullanılarak diş germleri, çene kemiği vediş köklerine bakıldı.Bulgular: Çalışmamızda yaş ortalaması 11,9±4,6 olan, 25’i kadın (%51,1), 24’ü erkek (%48,9) toplam 49 hasta değerlendirildi. Çalışmadaki ED’lihastaların oral bulguları ile ilgili olarak; %100 (n =49) diş eksikliği, %100 (n =49) mandibular protrüzyon ,%75,51 (n =37) konik diş, %6,12 (n =3)kök şekil anomalileri görülmüştür. Klinik muayenesinde ise terleme problemi %77.55 (n =38), saç-kıl anomalisi %95.91 (n =47), anormal parmak vetırnaklar %83.67 (n =41) belirlendi.Sonuç: ED’nin temel bulguları oral ve maksillofasiyal bölgede oluştuğundan, estetik ve çiğneme problemleri ortaya çıkmaktadır. Bu nedenle dişhekimliğinde multidisipliner tedavi gerektiren özel bir yere sahiptir. Bu hastalarda yaşam kalitesini artırmaya yönelik olarak tıp ve diş hekimlerininkoordineli çalışması oldukça önem kazanmaktadır.Öğe Evaluation of dentists’ and dentistry faculty students’ knowledge about HIV/AIDS and approaches to the HIV/AIDS patients*(2020) Adıgüzel, Özkan; Erpaça, Begüm; Sonkaya, Ezgi; Cangül, Suzan; Satıcı, Ömer; Tekin, SametBackground: This study is conducted to measure theknowledge of dentists and dentistry students about AIDS andto evaluate their perspectives, attitudes and behaviors towardsHIV-infected individuals.Material and Methods: This study was conducted on DicleUniversity Faculty of Dentistry 4th and 5th grade students anddentists. As a result of 2 different questionnaires, evaluationsare made on the knowledge of dentists and students about thedisease, how they behave towards the patients and theirdeficiencies. One Way ANOVA test is used for statisticalanalysis.Results: When the results of the first questionnaire wereconsidered in the evaluation of the data, the most correctlyanswered question is ‘‘It is not possible to infect HIV to thepatient from healthcare provider’ with 93.6%“disagree”response and the most incorrectly answered question is ‘If thepatient's HIV antibodies are positive, the patient is absolutelyimmune’ with 30.8% “disagree” response.Conclusions: According to the surveys and analysis dentistsand dentistry faculty students have knowledge about HIV/ AIDSbut it is not sufficient. Their negative perception of thesepatients need to be worked on. For this reason, HIV infectionrelated trainings should be organized for dentists and dentistrystudentsÖğe Evaluation of the use of PEEK material in post-core and crown restorations using finite element analysis(Mosher & Linder, Inc, 2020) Tekin, Samet; Adiguzel, Ozkan; Cangul, Suzan; Atas, Osman; Erpacal, BegumPurpose: To compare the stresses generated after the use of low elastic modulus polyetheretherketone (PEEK) as dental post and crown material with glass fiber post and metal supported ceramic crowns using finite element analysis. Methods: First an image of a maxillary central incisor taken on micro-computed tomography (microCT) was uploaded to a computer program. Modeling was made of all the materials in the computer environment and 3-dimensional (3D) virtual models were obtained. Using two different post materials (glass fiber and PEEK post) and two different crown materials (metal supported ceramic and PEEK crown), the modeling of the maxillary central tooth was completed and a total of four groups were obtained. Finally, 135 degrees and 100 N forces were applied from the midpoint of the palatal surface. Results: The FEA analysis showed the use of PEEK as post material decreased the stress values in the post, post cement and composite core models and did not have any significant change in the dentin and crown cement models. The use of composite veneer with PEEK substructure as crown material reduced stress values in dentin, the post and composite core and increased stress values in both the post cement and the crown cement.Öğe An evaluation using micro-CT data of the stress formed in the crown and periodontal tissues from the use of PEEK post and PEEK crown: A 3D finite element analysis study(Uluslararası Diş Araştırmaları Birliği, 2018) Tekin, Samet; Adıgüzel, Özkan; Cangül, SuzanAim: Metal-supported ceramics as crown material and glass fiber posts asdental post materials are in frequent current use. In recent years, it hasbeen claimed that stress-based biomechanical problems in dentistry canbe resolved with the benefit of the low elasticity modulus ofpolyetheretherketone (PEEK) material. The aim of this study was to usefinite element analysis (FEA) to compare the stresses formed by forcesapplied after the use of PEEK material as dental post and crown materialas an alternative to glass fiber posts and metal-supported ceramic crowns.Methodology: The stress analysis method used in this study was FEA.First, micro-computed tomography (micro-CT) images were obtained of amaxillary central incisor tooth and the data of the post materials scannedwith a 3-dimensional (3D) laser scanner were uploaded to a computerprogram. 3D models were obtained with designs made in the computerprogram of all the materials. The modelling of a maxillary central toothwas completed using 2 different post materials (glass fiber and PEEK) and2 different crown materials (metal ceramic and PEEK) and 4 groups wereformed for analysis. By applying force of 100 N at 135ofrom the absolutecentral point of the palatinal surface of the tooth, the stress values anddistribution occurring in the 3D periodontal models were compared.Results: The use of PEEK post reduced the stresses occurring on theperiodontal ligament (PDL) and the cortical bone, and caused no significantchange in the stresses on the crown. The use of PEEK crown reduced thestresses occurring on the crown and increased the stresses occurring on thePDL and cortical bone.Conclusions: With further in vitro and clinical studies of PEEK material,it can be considered that within a short time PEEK post and PEEK crowncould be in routine use in dentistry.Öğe Farklı kahve türlerinde bekletilen kompozit rezinlerin renk stabilitelerinin incelenmesi(Yeditepe Üniversitesi Diş Hekimliği Fakültesi, 2020) Cangül, Suzan; Adıgüzel, Özkan; Ünal, Server; Tekin, Samet; Sonkaya, Ezgi; Erpaçal, BegümAmaç: Bu çalışmadaki amaç pH dereceleri farklı kahve türlerinin estetik amaçla kullanılan kompozit rezinlerin renk değişimine etkisini değerlendirmektir. Gereç ve Yöntem: Çalışmada 4 farklı kompozit rezin (Estelite Sigma Quick, G-Aenial, Clearfil Majesty Esthetic, Ceram X One) ve 5 farklı kahve çeşidi (Nescafe, Ethiopia, Colombia, Veranda ve Türk kahvesi) kullanılmıştır. Her bir kompozit rezinden 40’ar tane olacak şekilde 2 mm derinliğinde 8 mm çapında silindir şeklinde toplam 160 tane disk hazırlandı. Her kahveye 8 adet kompozit disk konulacak şekilde rezin grupları 5 alt gruba ayrıldı. 24 saat, 48 saat ve bir hafta kahve solüsyonlarında bekletilen kompozit rezinlerin her bekletme sonrası renk ölçümleri tekrarlandı. Ölçümler Vita easyshade ölçüm cihazı ile yapıldı. İstatistiksel analizler tek yönlü varyans analizi (one-way ANOVA), Post-hoc, Friedman ve Ki-kare testleri kullanılarak yapıldı. (p=0,05). Bulgular: İstatistiksel değerlendirmeler sonucunda en fazla renklendirmeye sebep olan bekletme solüsyonu nescafe, en az renklenen kompozit rezin ise Clearfil Majesty olarak belirlenmiştir. Estelite Sigma Quick diğer rezinlere oranla daha fazla renklenme göstermiştir. Sonuç: Bu çalışmada kahve türlerinin restoratif materyallerde ciddi renklenmelere neden olduğu, fakat yapılan çalışmaların azlığı nedeniyle yeni klinik çalışmalara ihtiyaç duyulduğu sonucuna varılmıştır.Öğe pH değerleri farklı kahve türlerinde bekletilen kompozit rezinlerin yüzey pürüzlülüğünün değerlendirilmesi(2020) Cangül, Suzan; Adıgüzel, Özkan; Öztekin, Faruk; Satıcı, Ömer; Tekin, SametAmaç: Bu çalışmanın amacı pH dereceleri farklı 5 kahveçeşidinin 4 farklı kompozit rezin üzerinde farklı periyodlardaoluşturduğu yüzey pürüzlülük miktarını değerlendirmektir.Gereç ve yöntemler: Çalışmada her kompozit grubundan(Estelite Sigma Quick, G-Aenial, Clearfil Majesty, Ceram X One)50 adet örnek hazırlandı. 2 mm derinliğinde 6 mm çapında eşitolarak hazırlanan disklere kompozit rezinler yerleştirildi. Her birörnek polimerize edildi ve polisajları yapıldı. Deney öncesiörnekler 24 saat distile suda bekletildi ve profilometre cihazıkullanılarak ilk yüzey pürüzlülük değerleri kaydedildi. Herkompozit grubu 5 alt gruba ayrıldı. Sonrasında 1. gün, 2. gün ve7. gün olacak şekilde kahvelerde (Nescafe, Türk kahvesi,Ethiopia, Colombia, Veranda) bekletilen örneklerin tekrar yüzeypürüzlülük ölçümleri yapıldı. Çalışmanın analizinde tek yönlüvaryans analizi (ANOVA) ve Tamhane’s T2 testleri (post hocçoklu karşılaştırma testi) kullanıldı.Bulgular: Kahvelerde bekletilen örneklerin 24 ve 48 saatsonundaki yüzey pürüzlülük sonuçlarının istatistiksel analizindeen fazla Ethiopia kahvesinde bekletilen Clearfil Majesty’de, enaz ise Veranda kahvesinde bekletilen Estelite Sigma Quickrezininde pürüzlülük oluşmuştur. 7. gün sonunda ise Nescafedebekletilen Ceram X One kompozit disklerinde oluşan yüzeypürüzlülüğü çok düşük değerlerde görülmüştür.Sonuç: Sonuç olarak kompozit rezinlerin yüzey pürüzlülüğündegünlük tüketilen yiyecek ve içeceklerin sadece pH’sının değil,başka birçok faktörün de etkisi olduğu belirlenmiştir.Öğe Titanyum abutment ve metal destekli restorasyonlara alternatif peek materyallerinin kullanımı sonrası peri-implant kemikte, implantta, kronda, abutmentta ve vidada oluşan streslerin sonlu elemanlar stres analizi ile karşılaştırması(Dicle Üniversitesi, Diş Hekimliği Fakültesi, 2017) Tekin, Samet; Değer, YalçınGünümüzde teknolojinin ve insan sağlığına verilen önemin artmasıyla implant tedavileri artmıştır. İmplant tedavileri gerçekleştirildikçe bu tedavilerin başarısını arttırmak için yapılan çalışmalar da artmaktadır. İmplant tedavisinde titanyum, dayanak olarak yüksek başarı oranlarıyla kullanılmaktadır. Benzer şekilde metal alaşım destekli porselenler rutin olarak kullanılan materyallerdir. İmplantların ağızda sağlıklı ve uzun süreli kalması için ise en uygun biyomekanik koşullar sağlanmalıdır. Kortikal ve trabeküler kemikte oluşan ve kemik rezorpsiyonuna neden olan stresler, implant materyallerinden, implant tasarımından, üst yapı materyallerinden, üst yapı materyallerinin tasarımından ve yükleme koşullarından etkilenmektedir. İmplant tedavisinin başarısını daha üst seviyelere çekmek için birçok çalışma yapılmaktadır. Üç boyutlu sonlu elemanlar stres analizi gerek maddi açıdan gerekse hassas olmasına karşın kolay uygulanabilirliği sayesinde birçok mühendislik alanı ile son zamanlarda tıp ve diş hekimliğinde de kullanımı oldukça yaygındır ve in vivo çalışmalarla tespit edilmesi mümkün olmayan birçok stres analizinin bilgisayar ortamında rahatlıkla uygulanmasını sağlamaktadır. PEEK (poli-eter-eter-keton) biyouyumluluğu, beyaz rengi ve kemiğe yakın mekanik özellikleri sayesinde kron köprü restorasyonları, implant tedavisi ve hareketli protetik restorasyonlarda alt yapı ve üst yapı materyali olarak kullanılabilmektedir. Çalışmamızın amacı titanyum abutment ve metal destekli restorasyonlara alternatif PEEK materyallerini kullanarak yükleme sonrası peri-implant kemikte, implantta, üst yapıda, abutmentta ve vidada oluşan stresleri sonlu elemanlar stres XXIV analizi sayesinde karşılaştırmak ve neticesinde boyun rezorpsiyonlarını daha düşük seviyelere çekmeye çalışmaktır. GEREÇ VE YÖNTEM Çalışmamızda 3,8 mm çaplı 10,5 mm boyunda 4 adet titanyum implant üzerine; 2 adet titanyum, 2 adet PEEK abutment, üst yapı olarak da 2 adet metal destekli porselen ve 2 adet monolitik üretilen PEEK üst santral restorasyonun 3 boyutlu modellemesi yapıldı ve 4 ayrı grup elde edildi. Kortikal ve spongioz kemiğin ve kullanılan materyallerin meshing işlemi sonrası poisson oranı ve young modülü değerleri programa yüklendi. Üst santral dişin palatinal yüzeyine insizal kenarın 2 mm altından uzun eksene 45°'lik 178N oblik kuvvet uygulandı ve analiz gerçekleştirildi. Peri-implant kemikte, implantta, üst yapıda, abutmentta ve vidada oluşan en yüksek çekme, basma ve Von Mises stres değerleri dağılımları incelendi ve birbirleriyle karşılaştırıldı. BULGULAR VE SONUÇLAR Peri-implant kemikte meydana gelen stresler tüm gruplar incelendiğinde; birbirine oldukça yakın seviyelerdedir. Fakat kemikte meydana gelen stresler kron materyalinin değişimi sonucu, abutment materyalinin değişimine göre daha fazla etkilenmiştir. Kemikte meydana gelen stresler; kron materyali olarak metal destekli seramik kron, abutment materyali olarak ise PEEK abutment kullanımı sonucu kemikte daha az stres oluşumu gözlenmiştir. İmplantta meydana gelen stresler tüm gruplar incelendiğinde; kron materyalinin değişiminden belirgin bir şekilde etkilenmemiştir. Abutment materyalinin değişimi sonucu ise, elastik modülü daha fazla olan titanyum abutmentların kullanımı ile implantta meydana gelen streslerin, PEEK abutmentların kullanımı sonrası meydana gelen streslere göre daha az olduğu gözlenmiştir. Abutmentta meydana gelen stresler tüm gruplar incelendiğinde; abutment materyalinin değişimi sonucu kron materyalinin değişimine göre daha fazla etkilenmiştir ve elastik modülü az olan PEEK abutmentların kullanımı ile PEEK, kendi üzerindeki stresleri implanta ve vidaya iletmesi sonucu abutmentta daha az XXV stres oluşumu sağlamıştır. Kron materyali olarak ise PEEK kron kullanımı, yine abutmentta meydana gelen streslerde azalma sağlamıştır. Kronda meydana gelen stresler tüm gruplar incelendiğinde; abutment materyali açısından titanyum abutment kullanılan gruplarda, PEEK abutment kullanılan gruplara göre daha az stres oluşumu gözlenmiştir. Kron materyali açısından ise PEEK kron kullanılan gruplarda PEEK, kendisi üzerinde meydana gelen streslerin, metal destekli seramik kron kullanılan gruplara göre daha az olmasını sağlamıştır. Vidada meydana gelen stresler tüm gruplar incelendiğinde; abutment materyali açısından titanyum abutmentların kullanımı ile çok daha az stres oluşumu gözlenmiştir. Kron materyali açısından ise PEEK kron kullanımı, titanyum abutment üzerinde kullanıldığı gruplarda vidada meydana gelen stresleri azaltmış, PEEK abutment üzerinde kullanıldığında ise PEEK kron kullanımı vidada meydana gelen stresleri arttırmıştır. PEEK materyali, gelen kuvvetler sonucu kendisinin üzerinde oluşan stresleri tüm testlerde azalttığı gözlenmiştir. Çalışmamızın sonunda protetik materyallerin değiştirilmesiyle implant sisteminde streslerin azaltılabileceği görülmektedir. Çalışmamızın sonuçları in vitro ve in vivo olarak uzun süreli araştırmalar ile desteklenmesi gerekmektedir. Modifikasyonlar ve materyal özelliklerinin iyileştirilmesi ile PEEK materyalinin klinik diş hekimliği uygulamalarının arttırılabileceği görüşündeyiz.