Yazar "Güven, Sedat" seçeneğine göre listele
Listeleniyor 1 - 7 / 7
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe DİŞHEKİMLİĞİ PRATİĞİNDE EN SIK KULLANILAN 3 FARKLI SERT BESLEME MATERYALİ VE 1 ADET OTO POLİMERİZAN AKRİLİK REZİNİN POLİMERİZASYON DEĞERLERİNİN ÖLÇÜLMESİ: BİR LABORATUVAR ÇALIŞMASI(2015) Yıldız, İsmail; Demirci, Fatih; Aydoğdu, Yıldırım; Güven, Sedat; Agüloğlu, Süleyman; Eratilla, VeyselAmaç: Bu çalışmamızda 3 farklı sert besleme materyali ve 1 adet oto polimerizan akrilik rezin arasındaki polimerizasyon özellikleri karşılaştırıldı. Ağız içi ortamı taklit eden bir alet vasıtasıyla, polimerizasyon süresi, polimerizasyon sıcaklığı ve entalpideki değişiklik değerlendirildi. Materyal ve Metot: Çalışmamızda 3 farklı sert besleme materyali (Ufi Gel Hard, Elite Hard Relining, and GC Reline) ve 1 adet oto polimerizan akrilik rezin (SC Self-Cure Acrylic) kullanıldı. Deney Fırat Üniversitesi Fen Fakültesi'nde gerçekleştirildi. Materyallerin analizinde, diferansiyel kalorimetri tarama cihazı (Sapphire-DSC) kullanıldı. Sonuçlar: Polimerizasyon esnasında entalpi değerindeki (p<0.001) ve sıcaklık değerindeki (p<0.05) değişimlerde istatistiksel olarak anlamlı sonuçlar bulundu. Sertleşme süresi açısından (p>0.05) ise materyaller arasında herhangi bir istatistiksel fark bulunmamıştır. Tartışma: Elite Hard Reline sert besleme materyali bütün kategorilerde en iyi sonuçları göstermiştir. GC Reline sert besleme materyalinin entalpi ve sıcaklık değerlerinde göstermiş olduğu sonuçlar bütün diğer materyallere oranla oldukça yüksek bulunmuşturÖğe Effects of crown retrieval on implants and the surrounding bone: A finite element analysis(Korean Academy of Prosthodontic, 2016) Özkir, Serhat Emre; Ünal, Server Mutluay; Yürekli, Emel; Güven, SedatPURPOSE. The aim of this study was to observe stress concentration in the implant, the surrounding bone, and other components under the pull-out force during the crown removal. MATERIALS AND METHODS. Two 3-dimensional models of implant-supported conventional metal ceramic crowns were digitally constructed. One model was designed as a vertically placed implant (3.7 mm × 10 mm) with a straight abutment, and the other model was designed as a 30-degree inclined implant (3.7 mm × 10 mm) with an angled abutment. A pull-out force of 40 N was applied to the crown. The stress values were calculated within the dental implant, the abutment, the abutment screw, and the surrounding bone. RESULTS. The highest stress concentration was observed at the coronal portion of the straight implant (9.29 MPa). The stress concentrations at the cortical bone were lower than at the implants, and maximum stress concentration in bone structure was 1.73 MPa. At the abutment screws, the stress concentration levels were similiar (3.09 MPa and 3.44 MPa), but the localizations were different. The stress at the angled abutment was higher than the stress at the straight abutment. CONCLUSION. The pull-out force, applied during a crown removal, did not show an evident effect in bone structure. The higher stress concentrations were mostly observed at the implant and the abutment collar. In addition, the abutment screw, which is the weakest part of an implant system, also showed stress concentrations. Implant angulation affected the stress concentration levels and localizations. Clinical implications . These results will help clinicians understand the mechanical behavior of cement-retained implant-supported crowns during crown retrieval.Öğe Evaluation of stress distributions in peri-implant and periodontal bone tissues in 3- and 5-unit tooth and implant-supported fixed zirconia restorations by finite elements analysis(Dental Investigations Society, 2015) Güven, Sedat; Beydemir, Köksal; Dündar, Serkan; Eratilla, VeyselObjective: In this study, it is aimed to compare the distribution of stress on periodontal and peri-implant bone tissues in 3- and 5-unit-dental and implant-supported zirconia restorations using finite element analysis. Materials and Methods: Stress distribution formed in periodontal and peri-implant bone tissues as a result of chewing forces was analyzed in dental and implant-supported three-dimensional (3D) finite element models of zirconia restoration with 5-unit placed on the numbers of 43, 44, 45, 46, and 47 and with 3-unit placed on the number of 45, 46, and 47. Four different loading conditions were used. 200 N force was applied in 30° from the buccal inclination of number 43, 45, and 47 restorations separately and totally 850 N force was applied in 30° from the buccal inclination of whole restoration. The study was performed through static nonlinear analysis with the 3D finite element analysis method. Results: Stress accumulation in bone tissues in the tooth-supported model was found less than in implant-supported models. Stress accumulation was observed in the cervical portion of the implant in implant-supported models, and stress accumulation was observed surrounding bone of roots in tooth-supported models. The highest stress values were occurred in 5 unit implant-supported model in all loadings. Conclusion: In posterior restorations increased in the number of supported teeth and implant can reduce the destructive forces on periodontal and peri-implant bone tissues and may allow longer period retention of the restorations in the mouth.Öğe The evalution of stress distributions in 3 and 5 unit dental and implant supported fixed zirconia restorations: finite element analysis(Sivas Cumhuriyet Üniversitesi, 2015) Güven, Sedat; Eratilla, Veysel; Beydemir, Köksal; Dündar, SerkanPurpose: In this study, it is aimed to compare the distribution of stress on teeth and implants in 3-and-5-unit-dental and implant supported zirconia restorations by using finite element analysis. Material and Method: Stress distribution formed in teeth and implants as a result of chewing forces was analyzed in dental and implant (Astra Tech Microthread Osseo Speed, Sweeden) supported models of zirconia restoration with 5-unit placed on the numbers of 43, 44, 45, 46 and 47 and with 3-unit placed on the number of 45, 46 and 47. The study was performed through static nonlinear analysis with the three-dimensional finite element analysis method. Results: The highest and the lowest stress were respectively found on the number of 45 and 47 in 3-unit tooth supported model. The highest and the lowest stress in 5-unit tooth supported model were respectively found on the tooth of number 45 and on the root apex of the implant of number 43. Stress accumulation was observed in the cervical portion of the implant in implantsupported models. Stress accumulation in the tooth-supported model was found less than in implant-supported modelsConclusion: The extreme forces on the dental and implant-supported restorations with increased units can reduce survival rate of restorations in mouth. In posterior restorations increased in the number of supported teeth and implant can reduce the destructive forces on teeth and implant and may allow longer period retention of the restorations in the mouth.Öğe İmplant destekli ve diş destekli sabit köprü protezlerinde, stres dağılımının finite element analiz yöntemi kullanılarak karşılaştırılması(2016) Güven, Sedat; Beydemir, KöksalFinite element metodu dişhekimliği araştırmalarında son zamanlarda sıkça kullanılmaya başlanan bir yöntemdir. FEM (Finite element metodu) yöntemini kullanırken, üç boyutlu dijital görüntülere sahip olmak çok önemlidir. Bu çalışmada implant destekli ve diş destekli sabit köprü protezlerinde, stres dağılımının üç boyutlu 1/1 dijital görüntüleme yöntemi ile finite element analiz yöntemi kullanılarak karşılaştırılması amaç olarak ele alınmıştır. FEM mühendislik alanında yaygın kullanılan bir stres analiz yöntemidir. Dişhekimliğinde yeni yeni kullanılmaya başlanmıştır. Literatürlerde genellikle statik değişkenlere değinilmiştir. Bu çalışmamızda fakültemize yeni alınan “ICAT” 1/1 dijital görüntüleme cihazıyla ağız ortamı bilgisayara aktarılarak dinamik değişkenlere de bakma imkanı doğacaktır. Bu çalışmamızda 3 ve 5 üyeli implantüstü sabit köprü protezler ile 3 ve 5 üyeli diş destekli sabit köprü protezlerinin üzerine gelen çiğneme kuvvetleri arasındaki farka bakılacaktır. Bu şartları taşıyan tedavileri yapılmış hastaların üç boyutlu 1/1 dijital görüntüleme yöntemi ile kayıtları alınarak çenelerin modelleri elde edilecektir. Bu modeller ağız içinin dinamik yapısını gösterecektir. Modeller bilgisayar ortamında finite element analizi yöntemi ile çiğneme kuvvetlerine maruz bırakılıp aralarındaki farka bakılarak dayanıklılık bakımından kıyaslanacaktır. Finite element analizi yöntemi çok popüler olmasına rağmen, literatürde bu konu ile alakalı yeterli kaynak olmadığından böyle bir çalışmanın gerekliliği düşünülmüştür. Anahtar sözcükler : 1. Finite Element Analizi 2. Dental İmplant 3. Kemik Yüklemesi 4. Porselen Yapı 5. Stres DağılımıÖğe Manyetik Rezonans Görüntülemenin diş hekimliğinde kullanımı ve dental materyallere etkileri(Atatürk Üniversitesi Diş Hekimliği Fakültesi, 2018) Karaman, Tahir; Eşer, Bekir; Güven, Sedat; Yıldırım, Tuba TaloRadyolojik görüntüleme yöntemlerinden biri olan Manyetik Rezonans Görüntüleme, hastalıkların tanısına çok önemli katkıları bulunmasından dolayı yaygın bir şekilde medikal alanda kullanılmaktadır. Bu görüntüleme tekniğinde kuvvetli manyetik alan oluşması ve vücutta bulunan metalik objelerin bu manyetik alandan etkileşimleri hasta açısından potansiyel sağlık riskleri oluşturabilmektedir. Diş hekimliği alanında yaygın bir şekilde kullanılan Dental implantlar, Ortodontik braketler ve teller, Metal destekli sabit ve hareketli restorasyonlar vb. gibi içeriğinde metal bulunan objelerin varlığında Manyetik Rezonans Görüntülemesi esnasında oluşabilecek manyetik alan etkileşimlerinin yeterince bilinmesi gerekir. Görüntüleme esnasında hasta açısından oluşabilecek riskleri en asgari düzeye indirebilmek için vücutta bulunan ve manyetik alandan etkilenen metalik objeler ile ilgili gerekli tedbirlerin alınması gerekir.Öğe Prosthetic treatment in dentinogenesis imperfecta type II: a case report(2016) Güven, Sedat; Demirci, Fatih; Koparal, Mahmut; Tanik, AbdulsametINTRODUCTION:Dentinogenesis imperfecta (DI) or hereditary opalescent dentin is an autosomal dominant disorder affecting both primary and permanent dentition. Early diagnosis and treatment of DI is important for normal facial growth and esthetic continuity by preserving occlusion and tooth structure. It also provides psychological motivation by increasing the patient's quality of life. Providing functional dentition in DI patients prevents loss of the vertical dimension, while enabling normal growth of the facial bones and jaw joint.CASE REPORT:A 20-year-old male with DI was referred to our clinic with chewing difficulty and esthetic and speech problems. His brother also had this disease. Oral examination showed the loss of many teeth and the absence of enamel on most of the remaining teeth, causing discoloration and exposing soft dentinal tissue with calcification disorder. Despite widespread attrition of the teeth, pulp chambers were not exposed. The tip of the lower jaw was prominent in the patient's profile. Placing metal-ceramic fixed dentures in the lower jaw and an overdenture prosthesis in the upper jaw improved the patient's psychological state as well as his function, phonation, and esthetics.CONCLUSION:This case report presents the intraoral findings in a patient with DI, including the histopathological findings, and the prosthetic treatment approach and the treatment outcome.