Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Bako, Derya" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney
    (Springer Science and Business Media, 2023) Bako, Derya; Köksoy, Adem Yasin; Turmak, Mehmet
    Background Accurate estimation of kidney size and volume in the solitary functioning kidney is crucial because of a higher risk of developing kidney injury. MRI is an accurate method and is suitable for kidney volume measurement. Usually, axial axis images and measurement methods are preferred for kidney volume measurements. However, the anteroposterior diameter of the kidney is smaller than the longitudinal diameter, meaning that imaging in the coronal axis could provide needed information in a shorter time, enabling imaging of younger patients without sedation. Therefore, the purpose of this study was to compare coronal and axial axis kidney volume measurement methods and evaluate intra-observer and inter-observer reliability. Methods Axial axis T2W and coronal axis FIESTA images of kidneys were obtained with 10 mm slice thickness and no slice gap in pediatric patients with congenital solitary kidneys. Free-hand manual tracing was used to calculate volumes in both methods. Images were analyzed by two operators with diferent levels of experience. The expert operator computed solitary kidney volume twice in both methods for the intra-observer reliability, while the beginner operator’s measurements were used for the inter-observer reliability. Results High intra-observer (0.965 for axial and 0.972 for coronal) and inter-observer reliability were revealed (0.964 for axial and 0.963 for the coronal) for both measurement methods. Conclusion The coronal plane volume measurement method, which has a signifcantly shorter examination and post-processing time, is a highly reproducible and reliable method that can enable volume measurement with MRI in younger children, as the imaging time will be shortened.

| Dicle Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Dicle Üniversitesi, Diyarbakır, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim