Koroner stentlerin görüntülenmesinde 64 dedektörlü çok kesitli bilgisayarlı tomografi koroner anjiografinin tanısal değeri
dc.contributor.advisor | Bilici, Aslan | |
dc.contributor.author | Meriç, Kaan | |
dc.date.accessioned | 2016-04-13T07:35:21Z | |
dc.date.available | 2016-04-13T07:35:21Z | |
dc.date.issued | 2016 | |
dc.date.submitted | 2007 | |
dc.department | Dicle Üniversitesi, Tıp Fakültesi, Radyoloji Anabilim Dalı | en_US |
dc.description.abstract | Özellikle son 15 yılda koroner arterlere stent uygulamasındaki artış, günümüzde stent patensisini değerlendirmek için ucuz ve noninvaziv yöntem gerekliliğini ortaya çıkarmıştır. Tam bu noktada elektron beam BT ve MR koroner anjiografiye göre belirgin üstünlüğü bulunan 64 dedektörlü ÇKBT koroner anjiografi, invaziv konvansiyonel koroner anjiografiye pratik alternatif olarak karşımıza çıkmaktadır. Stentlerin yapısal özelliklerinden kaynaklanan artefaktlara rağmen son jenerasyon 64 dedektörlü ÇKBT cihazları ile yapılan çalışmalarda (ki çalışmamızda da bu sonuçlar doğrulanmıştır) stent lümeninin görüntülenmesinde başarılı olunmuş, hatta minimal neointimal hiperplaziler bile teşhis edilir olmuştur. Biz çalışmamızda 64 dedektörlü ÇKBT koroner anjiografinin koroner stentlerin restenoz ve oklüzyonunu değerlendirmedeki diagnostik performansını ortaya koymaya çalıştık. Kliniğimize Ekim 2006 ile Haziran 2007 tarihleri arası başvurmuş koroner stenti bulunan 25 hastaya(18 erkek 7 kadın) 64 dedektörlü ÇKBT koroner anjiografi tetkiki yapıldı. Başvuran hastaların ortalama yaşı 57 olup en genci 40 yaşında, en yaşlısı 82 yaşında idi. ÇKBT koroner anjiografi yapılan 25 hastadaki toplam 33 stent değerlendirilmeye alındı. İnceleme retrospektif EKG tetiklemeli ve otomatik bolus-tracking yöntemi ile yapıldı. Her bir stente Philips Brilliance CT cihazındaki 4 kardiak filtre (CA cardiac smooth; CB cardiac standart; CC cardiac sharp; CD cardiac detailed) uygulandı. Değerlendirmeler iki radyolog (A.B, K.M) tarafından ÇKBT anjiografi sonrası 2-3 gün içinde yapıldı. 64 dedektörlü ÇKBT koroner anjiografide 33 stentin 9 (%27)’si oklüze, 24 (%73)’si ise patentti. Patent stentlerin 5’inde neointimal hiperplazi, 2’sinde ise kritik restenozlar tespit edildi. Çalışmamız sonucunda 64 dedektörlü ÇKBT koroner anjiografinin stent restenoz ve oklüzyonunun tespitinde noninvaziv güvenilir bir yöntem olduğunu tespit ettik. | |
dc.description.abstract | Considering the high number of percutaneous coronary interventions that involve stent implantation, the development of relatively inexpensive and noninvasive methods for assessing stent patency is an issue of growing interest. 64 section multidetector CT has recently emerged above competing modalities such as electron-beam CT and MR imaging as a practical alternative to invasive coronary angiography. Despite image-degrading effects caused by the metallic scaffold of the stent, recent experience with the current generation of 64-section scanners suggests improved assessability of the in-stent lumen with the capability to appreciate more subtle degrees of in-stent neointimal hyperplasia. To prospectively assess the diagnostic performance of 64- section multidetector computed tomography (CT) for the evaluation of coronary stent stenosis and occlusion. We evaluated 25 patients who had 33 stents between October 2006 and June 2007 by using 64-section multidetector CT. Twentyfive patients (18 men, 7 women; mean age, 57 years; range, 40–82 years) with 33 coronary stents were examined with 64-section multidetector CT. Scanning was retrospectively electrocardiographically gated, and an automatic bolus-tracking method was used. For image reconstruction, CA cardiac smooth; CB cardiac standart; CC cardiac sharp; CD cardiac detailed kernel was used. Evaluations were performed by two radiologists (A.B, K.M) within 2–3 days after MDCT. At 64-section multidetector CT angiography, 9 (27%) of the 33 stents were shown occluded and 24 (73%) of the 33 stents were shown patent. 5 of patent stents had neointimal hyperplasia and 2 of patent stents had critical restenosis. Sixty-four–section multidetector CT coronary angiography is a promising method for the noninvasive diagnosis of in-stent restenosis and occlusion. | |
dc.identifier.uri | https://hdl.handle.net/11468/1822 | |
dc.institutionauthor | Meriç, Kaan | |
dc.language.iso | tr | en_US |
dc.relation.publicationcategory | Tez | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Koroner arter | en_US |
dc.subject | Coronary arter | en_US |
dc.subject | Kalp hastalıkları | en_US |
dc.subject | Heart diseases | en_US |
dc.subject | Çok kesitli bilgisayarlı tomografi | en_US |
dc.title | Koroner stentlerin görüntülenmesinde 64 dedektörlü çok kesitli bilgisayarlı tomografi koroner anjiografinin tanısal değeri | en_US |
dc.type | Doctoral Thesis | en_US |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- Koroner stentlerin görüntülenmesinde 64 dedektörlü çok kesitli bilgisayarlı tomografi koroner anjiografinin tanısal değeri - Kopya.pdf
- Boyut:
- 2.21 MB
- Biçim:
- Adobe Portable Document Format
Lisans paketi
1 - 1 / 1
[ X ]
- İsim:
- license.txt
- Boyut:
- 1.71 KB
- Biçim:
- Item-specific license agreed upon to submission
- Açıklama: