Titanium Implant Medialization Laryngoplasty Application in the Case of a Silicone and Gore-Tex Extrusion
Tarih
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Erişim Hakkı
Özet
Though the surgical technique of medialization laryngoplasty (ML) has been standardized today, the ideal implant has not been well-defined yet. Various non-absorbable materials such as autogenous cartilage, silicone, hydroxylapatite, Goretex, and titanium have been used for ML Titanium implant ML is a new technique and any complication has not been reported so far. Core-tex and silicone implants have been used more longer and both of them are accepted safe and easy to handle materials. Extrusion of Gore-ten or silicone material after ML has been rarely reported. We present a case of a 38-year-old man with history of silicone and then Gore-tex implant extrusion after ML Titanium implant was performed on the patient. Although rare, the possibility of silicone and Gore-ten extrusion after MT operation must not be ignored. Titanium implant may be a good alternative in such cases.